60 50 0 to 120 30 to 200 0 to 60 0 to 250 20 to 150 X X X X The above table covers only general characteristics of subject rubber materials.

-10B: ZP3-13B: ZP3-16B: P.52 ZP3B-Y2BK6-B5 Mounting Adapter Part No.

-10B: ZP3-13B: ZP3-16B: P.52 ZP3B-Y2BK6-B5 Mounting Adapter Part No.

-10B: ZP3-13B: ZP3-16B: P.52 ZP3B-Y2BK6-B5 Mounting Adapter Part No.

-10B: ZP3-13B: ZP3-16B: P.52 ZP3B-Y2BK6-B5 Mounting Adapter Part No.

-10B: ZP3-13B: ZP3-16B: P.52 ZP3B-Y2BK6-B5 Mounting Adapter Part No.

SOL.A 10B Black 6 stations Manifold Specifications Example Stations 1 2 3 4 5 6 COM.

B 10A (+) () 10B (+) () () COM (+) Note) Positive COM spec. Negative COM spec.

Seal Coil voltage 1 100 VAC (50/60 Hz) 2 200 VAC (50/60 Hz) 3 110 VAC (50/60 Hz) 4 220 VAC (50/60 Hz) 5 24 VDC 6 12 VDC Series Enter in order starting from the first station on the D side.

SOL.A 8A () (+) Station 8 SOL.B 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 8B () (+) 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 9A () (+) Station 9 SOL.B 9B () (+) SOL.A 10A () (+) Station 10 SOL.B 10B () (+) Note) When using the negative COM specification, use valves for negative COM. (+) () COM Note) Negative COM spec.

SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 8B Station 8 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B SOL.A 9A 9B Station 9 SOL.B SOL.A 10A 10B Station 10 SOL.B COM COM. 668 Base Mounted Plug-in Unit VQC5000 Series T VQC5000 Kit (Terminal block box kit) IP67 compliant VV5QC51 SV L2 SYJ L1 10 88.7 (7.1) 59.5 P = 41 SZ Indicator light

CR-50500 Okaya Electric Industries) Rated C R voltage [ 30%] Test voltage Dimensions [Unit: mm] [F 20%] AC [V] Between terminals: 625 V AC, 50 Hz/60 Hz 60 s Between terminal and case: 2000 V AC 50/60 Hz 60 s Band (clear) AWG 18 Twisted wire (18.5 + 2) 1 15 1 Soldered 250 0.5 50 (1/2W) 3.6 CR-50500 6 1 6 1 300 min. 300 min. 48 1.5 16 1 (18.5 + 5) max.

9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring will be double wiring (connected to SOL. a and SOL. b) regardless

9B 10B 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A Station 2 Station 3 Station 4 Station 5 10A COM 10B Station 6 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B Station 7 Station 8 If alignment is not specified, the internal wiring will be double wiring (connected to SOL. a and SOL. b) regardless

Mixed single and double wiring is available as an option. 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.A 8A () (+) SOL.B 8B () (+) Station 8 SOL.A 9A () (+) SOL.B 9B () (+) Station 9 SOL.A 10A () (+) SOL.B 10B () (+) Station 10 Note) Mounting valve has no polarity. It can also be used as a negative common. Note) (+) () COM.

SOL.A 8A () (+) SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 8B () (+) 8 stations SOL.B 8B SOL.A 9A () (+) SOL.A 9A SOL.B 9B () (+) 9 stations SOL.B 9B SOL.A 10A () (+) SOL.A 10A SOL.B 10B () (+) 10 stations SOL.B 10B (+) () COM COM Note) There is no polarity.

SOL.A 8A () (+) SOL.A 8A 1A COM 2A 3A 4A 5A 6A 7A 8A 9A 10A 1B 1A 2B 2A 3B 3A 4B 4A 5B 5A 6B 6A 7B 7A 8B 8A 9B 9A 10B 10A COM 1B 2B 3B 4B 5B 6B 7B 8B 9B 10B SOL.B 8B () (+) 8 stations SOL.B 8B SOL.A 9A () (+) SOL.A 9A SOL.B 9B () (+) 9 stations SOL.B 9B SOL.A 10A () (+) SOL.A 10A SOL.B 10B () (+) 10 stations SOL.B 10B (+) () COM COM Note) There is no polarity.

Output circuit Surge voltage 24 V 0 V sol.1: Energized 60 V R Surge voltage Internal circuit 24 V 0 V sol.2: De-energized 60 V R Surge voltage 24 V 0 V Large capacity load: Energized 60 V R Relay Power supply circuit breaker 24 VDC Figure 1.

Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.

Nil E Yes Without light, with surge voltage suppressor Seal Metal seal Rubber seal 0 1 Coil voltage Function 1 2 3 Stations 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC D side U side Standard type (1 W) Low wattage type (0.5 W) External pilot Nil Y R (1) (2) Applicable to DC sepecifications.