Hz 5.0 power 50 Hz 3.4 (VA) Holding 60 Hz 2.3 Power consumption (W) 1.8 Surge voltage suppressor and indicator light Available as option Note 1) Pilot pressure range should be 0.1 to 1 MPa (14.5 to 145 psi).
Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 24 VDC
Hz 200 VAC, 50/60 Hz 24 VDC 12 VDC Other Nil SB None With 10 10 stations VF Note) When equipped with control unit, 1 or 2 stations are used for mounting.
SQ Pilot Valve/Spacifications AXT511C-4 (V) AXT511C-1 (V) AXT511C-2 (V) AXT511C-3 (V) AXT511C-4 (V) 24V DC 12V DC AXT511C-1 (V) 100V AC 50/60 Hz 200V AC 50/60 Hz 0.049/0.043 0.024/0.021 0.031/0.02 0.015/0.01 Part No.
Hz 200 VAC, 50/60 Hz 24 VDC 12 VDC Other Nil SB None With 10 10 stations VF Note) When equipped with control unit, 1 or 2 stations are used for mounting.
specifications Item Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal block) Ambient temperature Operating: -10 to 50 oC Storage: -20 to 60
specifications Item Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal block) Ambient temperature Operating: -10 to 50 oC Storage: -20 to 60
specifications Item Specification Rated voltage 24 VDC 1 Allowable instantaneous electrical stop 1 msec. or less Enclosure IP20 Applicable standard UL/CSA, CE marked Withstand voltage 500 VAC 1 minute (between FG and external terminal block) Insulation resistance 10 M or more (500 VDC is given between FG and external terminal block) Ambient temperature Operating: -10 to 50 oC Storage: -20 to 60
C (F) note 2 -5~+50 (+23~+122) -20~+60 (-4~+140) Max.
Stations: 13 Stations, SUP, EXH Block Mounting: B (Both Sides 1~16 Stations), Pilot Specification: S (Internal Pilot w/Built-in Silencer)
Stations: 4 Stations, SUP, EXH Block Mounting: U (U Side 1~10 Stations)
Stations: 9 Stations, SUP, EXH Block Mounting: B (Both Sides 1~16 Stations), Pilot Specification: S (Internal Pilot w/Built-in Silencer)
Stations: 9 Stations, SUP, EXH Block Mounting: U (U Side 1~10 Stations)
Stations: 13 Stations, SUP, EXH Block Mounting: B (Both Sides 1~16 Stations)
Stations: 16 Stations, SUP, EXH Block Mounting: B (Both Sides 1~16 Stations)
Stations: 10 Stations, SUP, EXH Block Mounting: B (Both Sides 1~16 Stations), Pilot Specification: S (Internal Pilot w/Built-in Silencer)
Stations: 8 Stations, SUP, EXH Block Mounting: D (D Side 1~10 Stations)
Stations: 2 Stations, SUP, EXH Block Mounting: D (D Side 1~10 Stations)
Stations: 8 Stations, SUP, EXH Block Mounting: U (U Side 1~10 Stations)
Stations: 10 Stations, SUP, EXH Block Mounting: D (D Side 1~10 Stations)