Search Results "RZQL50-200-170"

suppressor AC ( Hz) 50 60 1 100 VAC 2 200 VAC With light/surge voltage suppressor YOZ is not available.

340 42 140 130 204 20 16 125 170 340 42 170 162 234 20 16 160 187.5 375 52 212 200 284 24 20 339 Series CHAW Dimensions Rod trunnion style: CHAWU Z T T Cushion adjustment screw 2 x Rc P Width across flats G Width across flats G V V TT GA Air release GA M 4 x J MM MM R (max.)

motor capacity [W] 100 200 400 Compatible encoder Absolute 20-bit encoder (Resolution: 1048576 p/rev) Main circuit power supply Power voltage [V] Three phase 200 to 230 VAC (50/60 Hz) Allowable voltage fluctuation [V] Three phase 170 to 253 VAC Control power supply Power voltage [V] Single phase 200 to 230 VAC (50/60 Hz) Allowable voltage fluctuation [V] Single phase 170 to 253 VAC Power

100 400 200 Absolute 18-bit encoder (Resolution: 262144 p/rev) Compatible encoder Three phase 200 to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Single phase 100 to 120 VAC (50/60 Hz) Main power supply Three phase 170 to 253 VAC Single phase 170 to 253 VAC Allowable voltage range [V] Single phase 85 to 132 VAC Rated voltage [A] 3.0 5.0 2.6 1.5 0.9 Control

T-slot 2 dimensions Compatible Motors Switch Internal Circuit D-Y7GL Motor output (W) Motor model Brake Manufacturer Power supply voltage (VAC) Motor specification symbol Controller driver model + Brown lead wire 100/110 200/220 100 200 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 100/115 200/230 LC1-1B1H1Without brake (Horizontal specification) Main circuit

Manifold Options 200 SY3000/5000/7000 Series Manifold Parts Nos.

125 130 120 140 150 170 190 210 230 250 290 Without Air Cushion Bore size (mm) S ZZ 32 40 50 90 90 102 141 145 164 63 80 100 102 124 124 164 200 200 Model without air cushion is designed to include rubber bumpers.

(mm) Bore size (mm) Stroke range (mm) F N M E L D C K A B J G H I AC AF AB AE AA AD AP 63 80 100 100 66 200 140 180 30 135 117 200 228 13.5 M16 x 2 depth 28 65 25 15 50 M12 x 1.75 depth 24 25 170 60 20 depth 4.5 75, 100, 125 150, 200 250, 300 115 76 234 214 170 30 160 230 262 13.5 M16 x 2 depth 28 138 75 27 15 55 M12 x 1.75 depth 24 30 200 70 20 depth 14.5 125 274 80 245 210 190 35 280 304

129 12 135 40 73 80 106 35 60 27 5.5 6 8 4 16 134 150 102 118 9 9 85 140 M8 35 25 75, 100, 125 149 16 170 50 93 95 134 50 75 34 6.5 9 10 7 19 170 186 134 150 9 9 105 175 M8 45 32 150, 200, 250 149 16 170 50 93 95 134 50 75 34 6.5 9 10 7 19 170 186 134 150 9 9 105 175 M8 45 40 300 182 19 194 55 103 115 152 56 90 38 7 11 12 7 21 190 210 140 160 11 12 115 200 M10 50 Long Stroke Bore size (mm

VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Single phase 200 VAC (50/60 Hz) Single phase 100 VAC (50/60 Hz) Three phases 200 VAC (50/60 Hz) Power source 90 130 0.4 0.45 1.44 1.4 50 60 0.4 0.35 55 65 0.8 0.9 38 46 132 x 2 170 x 2 0.23 0.26 50 Hz 60 Hz 50 Hz 60 Hz Power consumption (W) 0.46 0.52 Current (A) Compact size and lightweight Uses minimal floor

Absolute 20-bit encoder (Resolution: 1048576 p/rev) LEF Main circuit power supply Power voltage [V] Three phase 200 to 230 VAC (50/60 Hz) LEJ Allowable voltage fluctuation [V] Three phase 170 to 253 VAC Control power supply Power voltage [V] Single phase 200 to 230 VAC (50/60 Hz) LEL Allowable voltage fluctuation [V] Single phase 170 to 253 VAC Power supply capacity (at rated output) [A]

200 16 20 10, 25, 40, 50, 80, 100, 125, 160, 200, 250, 300 1000 25 Refer to pages 101 to 111 for cylinders with auto switches.

JIS Symbol Double acting, Double rod Standard Strokes (mm) Bore size (mm) Standard stroke 125, 140, 160 180, 200 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300 Made to Order (For details, refer to pages 177 to 207.)

30 50 100 150 200 250 300 30 50 100 150 200 250 300 Product weight [kg] 1 1.14 1.37 1.66 1.83 1.7 1.89 2.21 2.63 2.97 3.31 3.57 2.95 3.21 3.76 4.32 4.99 5.48 5.92 Series LEYG16LmE LEYG25LmE LEYG32LmE Stroke [mm] 30 50 100 150 200 30 50 100 150 200 250 300 30 50 100 150 200 250 300 Product weight [kg] 1.01 1.14 1.31 1.6 1.75 1.71 1.92 2.16 2.59 2.85 3.17 3.41 2.95 3.22 3.61 4.16 4.7 5.21

rate: 50% Stroke 300 mm Series MB, CA2 Pressure 0.5 MPa Load rate: 50% Stroke 500 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

(mm) Bore size (mm) 63 80 100 Stroke range (mm) B C D E F G H I J K L M N A AA AB AC AD AE AF AP 200 228 30 140 200 13.5 65 117 135 180 66 100 25 25 15 170 50 60 20 depth 14.5 M16 x 2 depth 28 M12 x 1.75 depth 24 75, 100, 125 150, 200 250, 300 230 262 30 170 234 13.5 75 138 160 214 76 115 30 27 15 200 55 70 20 depth 14.5 M16 x 2 depth 28 M12 x 1.75 depth 24 280 304 35 210 274 15 85 153 190

100 1500 1000 500 400 300 200 100 1500 1000 500 400 300 200 100 MY3B max.

MY1CW MY1MW 200 200 (kg) (kg) 190 190 (2100) (2100) (2100) (2100) 180 180 170 170 m 160 160 150 150 140 140 (2400) (2400) (2400) (2400) (2400) (2400) l 130 130 (1800) (1800) (1800) (1800) 120 120 Mass (m) Mass (m) 110 110 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) (2000) m l 90 90 (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 MY1MW50 MY1MW50 80 80 m (1600) (1600) (1600) (1600

Safety valve/ Pressure gauge set (Supplied with product) Connected to VBA22A Connected to VBA20A Tank IN port Rc3/8 Tank OUT port Rc1/2 Booster regulator IN port Rc3/8 Booster regulator IN port Rc3/8 EXH: Rc3/8 EXH: Rc3/8 Spare port Rc1/2 Spare port Rc1/2 454 442 417 367 367 OUT OUT 278 60 170 170 170 4 x 11 4 x 11 32 32 Drain port Rc1/4 Drain valve 120 120 312 180 180 522 500 The length