Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): null~1.0, Port thread type: NPT, Auto
Magnet: None, Bore Size: 40mm, Port Thread: Screw-in Piping, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End Configuration: Lever Style( Energy Absorption Adjustable), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: None, Bore Size: 40mm, Port Thread: Built-in One-touch Fitting, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End Configuration: Lever Style( Energy Absorption Adjustable), Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: NPT, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 20: M5 Thread, Bore 32 to 50: G, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 50mm, Water Resistant: None, Port Thread: NPT, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 25, Cylinder Operation Method: [Single Action Retraction] Single Acting, Spring Extend, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): null~1.0, Port thread type: NPT, Auto
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: T (Single Acting/Spring Extend), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: T (Single Acting/Spring Extend), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Single Acting/Spring Extend, Rod End: Lever Type, Adjustable Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: B (Lever Type, Adjustable Absorber Type)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: R (Roller Type)
Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting)