Your search for RSQ returned 30 result(s)
There were no hits with the full part number, but there were 5 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
D-A90L-900 cannot be mounted. Note 2) 90-RS(1)H series D-A90L-900 cannot be mounted. For 90-/91-MY1B and 90-/91-MY1H series For 90-/91-CY3R, 90-/91-MGP and 90-RS(1)H series 90-BMG2-012 90-BMG2-012 68
www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE E242 & N347 1.181 LOW PROFILE SLIDE TABLE SERIES MXF ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Type Electrical Entry Auto Switch Application Load Voltage Load Internal Indicator 24VAC/DC 50mA Reed Grommet D-A90L PLC 0 No 48VAC/DC 40mA 100VAC/DC 20mA
With One Unit A & One Unit H each LH With One Unit L & One Unit H each (For longer strokes please consult your local SMC Sales Office) ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove)
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: None, Port Thread: NPT, Stroke: 30mm, Action: Single Acting/Spring Extend, Rod End: Round Bar Style, Direct Mount Switch Groove: Direct Mount Switch Groove, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: L (Shipped Together Only for Mounting B)
Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 50mm, Water Resistant: None, Port Thread: NPT, Stroke: 30mm, Action: Single Acting/Spring Extend, Rod End: Round Bar Style, Direct Mount Switch Groove: Direct Mount Switch Groove, Mounting Bolt: Shipped Together Only for Mounting B, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product, and replaced byCDM2BZ40-30TZ, CYL, RND BODY, SGL ACTING, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, MT, 40MM CM2 SGL-ACT AUTO-SW, 1.65346 lb
This is a legacy product, and replaced byCJ2B10-30TZ, CYL, RND BODY, SGL/ACT, ACTUATOR, CJ2 ROUND BODY CYLINDER, ES, 10MM CJ2 SINGLE-ACTING, .17147 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CJ2Air cylinderCJ2Double acting, Single rodExcept with air cushion666
This is a legacy product, and replaced byCJ2B16-30TZ, CYL, SINGLE ACTING, SPR EXT, ACTUATOR, CJ2 ROUND BODY CYLINDER, GS, 16MM CJ2 SINGLE-ACTING, .24407 lb, SeriesDescriptionModelActionNoteVol. no. (for std model)CJ2Air cylinderCJ2Double acting, Single rodExcept with air cushion666
Example) D-A90L Solid State Switches Max. load current or load current range Current consumption Power supply voltage Internal voltage drop Applications Leakage current Indicator light Auto switch part no.
Example) D-A90L Solid State Switches Max. load current or load current range Current consumption Power supply voltage Internal voltage drop Applications Leakage current Indicator light Auto switch part no.
20 8 MTS 20 A90L 100 12 to 40 Bore size Number of auto switches Nil S 2 pcs. 1 pc. 12 16 20 25 32 40 12mm 16mm 20mm 25mm 32mm 40mm Auto switch type Without auto switch Nil Refer to the table below for auto switch part numbers.
Example) D-A90L Resistor DC power supply Load OUT Black [White] Reverse current prevention diode () DC () Blue [Black] Contact Protection Boxes/CD-P11, CD-P12 D-A9I and D-A9I type switches do not have internal contact protection circuits. 1. The operated load is an induction load. 2. The length of wiring to the load is 5m or more. 3. The load voltage is 100VAC.
Example) D-A90L Contact protection box OUT () Brown [Red] Reed switch CD-P11 OUT () Blue [Black] CD-P12 Auto Switch Weights D-A93(V) (g) D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Type Brown [Red] Contact protection box OUT (+) Brown [Red] Resistor Lead wire length 0.5m 7 7 6 7 8 8 Reed switch Zener diode Lead wire length 3m 35 35 30 35 41 41 CD-P11 OUT () Blue [Black] CD-P12 Blue [Black]
Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A90L