SMC Corporation of America
Elite Part Number Search
Search Results "RSDQB40-25DL-M9N"

As a rough guide, tighten the screw an additional 90 after feeling a tight resistance. 0.5 0.3 0.3 0.2 MHL2-16Dl 0.5 0.2 0.3 0.2 MHL2-20Dl 0.2 0.2 0.2 0.1 MHL2-25Dl 0.4 0.7 0.7 0.4 MHL2-32Dl 0.2 0.7 0.6 0.4 MHL2-40Dl MHZ2 MHZJ2 MHQ MHL2 MHR Made to Order Specifications MHK MHS 1 Oil proof 2 Thermal proof MHC2 D X 5 Cylinder bore size Stroke symbol Solid state switch MHL2 D X 4 Cylinder bore

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A76H--Reed, DC Volt.<5, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: B (Lever Type, Adjustable Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: Round Bar Style, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen.