As a rough guide, tighten the screw an additional 90 after feeling a tight resistance. 0.5 0.3 0.3 0.2 MHL2-16Dl 0.5 0.2 0.3 0.2 MHL2-20Dl 0.2 0.2 0.2 0.1 MHL2-25Dl 0.4 0.7 0.7 0.4 MHL2-32Dl 0.2 0.7 0.6 0.4 MHL2-40Dl MHZ2 MHZJ2 MHQ MHL2 MHR Made to Order Specifications MHK MHS 1 Oil proof 2 Thermal proof MHC2 D X 5 Cylinder bore size Stroke symbol Solid state switch MHL2 D X 4 Cylinder bore

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9N--Solid State , Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A76H--Reed, DC Volt.<5, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal

Magnet: Built-in, Mounting: Through Hole, Standard, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 25mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: Direct Mount Switch Groove, Mounting Bolt: None, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number:

The RSQ series is a fixed-height stopper cylinder with proven endurance and low breakaway characteristics. The RSG series is an adjustable mounting height stopper cylinder. It can be raised or lowered according to the distance required to stop the work piece. The RSH heavy-duty stopper cylinder is specially designed for use on conveyor lines or other applications requiring an external stopping

Magnet: None, Bore Size: 50mm, Port Thread: Screw-in Piping, Stroke: 25mm, Action: D (Double Acting), Rod End Configuration: L (Lever Style (Adjustment-free), Basic Style))