Your search for RSQ returned 30 result(s)
There were no hits with the full part number, but there were 5 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
As a rough guide, tighten the screw an additional 90 after feeling a tight resistance. 0.5 0.3 0.3 0.2 MHL2-16Dl 0.5 0.2 0.3 0.2 MHL2-20Dl 0.2 0.2 0.2 0.1 MHL2-25Dl 0.4 0.7 0.7 0.4 MHL2-32Dl 0.2 0.7 0.6 0.4 MHL2-40Dl MHZ2 MHZJ2 MHQ MHL2 MHR Made to Order Specifications MHK MHS 1 Oil proof 2 Thermal proof MHC2 D X 5 Cylinder bore size Stroke symbol Solid state switch MHL2 D X 4 Cylinder bore
LOW type KU C X2321 X2322 C Clamping height L H M9BVL 32 075 R A KU HIGH type Number of auto switches With lock Nil 2 pcs.
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type)
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
This is a legacy product, and replaced byCDQSB25-80DCM-M9BVL-XB10
, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9BVL
, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: M9BVL
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73H--Reed, DC Volt.>5,<24, AC Volt.<200, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 1 pc.
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73--Reed, DC Volt.>5,<24, AC Volt.<100, LED, Vertical, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F79--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Lever Type, Fixed Absorber Type, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: J79W--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: L (Lever Type, Fixed Absorber Type), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BV--Solid State , Gen. Purpose, 2 Wire, Vertical, Lead Wire or Prewired Connector: L