Your search for RSQ returned 30 result(s)
There were no hits with the full part number, but there were 5 hits in the keyword search.
There were no hits with the full part number, but there were 4 hits in the keyword search.
Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: K (Chamfered)
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -
AL With One Unit A & One Unit L each AH With One Unit A & One Unit H each LH With One Unit L & One Unit H each ACCESSORIES AUTO SWITCHES Note: Pre-wired Switches with 3/4 Pin Connectors available Bore Size Model Switch Type Load Voltage Load Current Power Internal Voltage Indicator Grommet Connector Source Drop Lamp 16 & 20 D-A90L Reed 24 V/48V/100 V AC/DC 50mA/40mA/20mA None 16 & 20 D-A93L
Thrust energy E2 Fs Fs+Mgs Fs-Mgs Absorption energy E3 ACCESSORIES AUTO SWITCHES E1+E2 Note: Pre-wired Switches with 3/4 Pin Connectors available, please consult SMC Customer Service Bore Model Switch Load Load Power Internal Indicator Size Grommet Connector Type Voltage Current Source Voltage drop Lamp 16 & 20 D-A90L Reed 24V AC/DC 50 mA None 48V AC/DC 40mA 100V AC/DC 20 mA 16 & 20 D-A93L
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: K (Chamfered), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: K (Chamfered), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MAPC (1.0m Cord Length
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: K (Chamfered), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: D (Double Acting), Rod End: K (Chamfered), Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M8-3 Pin Connector
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: None, Mounting Bolt: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: A73C--Reed, DC Volt.>5,<24, LED, Connector, Vertical, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F7P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Both Ends Tapped, Bore Size: 40mm, Water Resistant: -, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: Double Acting, Rod End: Chamfered, Direct Mount Switch Groove: -, Mounting Bolt: -, Auto Switch: F79W--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 5m, Number: -