This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, COMPACT W/LOCK, SW CAP, ACTUATOR, RLQ COMPACT LOCK CYLINDER, PE, 63MM RLQ DBL ACTING, AUTO-SW, .00000 lb
Model Wires[mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) (b) When using the 600V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire) Selection example of wire size when using HIV wires is indicated below.
Use wires 8) of the following sizes with the power regeneration converter (FR-RC-(H) :Mitsubishi Electric Corporation). Model Wires[mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) 13 15 13.
(FR-RC-(H) ())() [mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) (b) 600V (HIV ) HIV(FR-RC-(H) ())()(1)(a)IV 13.2 2(HIV) 2] (12) [mm L1L2L3 L11L21 UVW PC B1B2 BUBVBW OHS1OHS2 LECSC-S5 LECSC-S7 2(AWG14) 1.25(AWG16) 1.25(AWG16) 2(AWG14) 1.25(AWG16) LECSC-S8 1. (1)(c) 2. 13 15 13 (c) (1)(a) (b) (2) a FVD5.5
Insert the radio noise filter (FR-BIF-(H) (Mitsubishi Electric Corporation)) on the power cables (Input cables) of the driver. 7) 2. Insert the line noise filter (FR-BSF01 FR-BLF (Mitsubishi Electric Corporation)) on the power cables of the driver.
T E C H N I C A L SPECIFICATIONS COMBINATION OF OPTIONS POSSIBLE WITH STROKE ADJUSTERS: T E C H N I C A L SPECIFICATIONS FORMULA FOR CALCULATION OF ALLOWABLE STATIC LOAD, FP, FY, AND FR Stroke No Buffer End Axial Buffer + Buffer + Adjuster Option Spring Lock Piping End Lock Axial Piping F R P FR FP None YES YES YES YES YES YES AS (Front) YES YES YES YES YES YES AT (Rear) YES YES NO NO NO
Insert the radio noise filter (FR-BIF (Mitsubishi Electric Corporation)) on the power cables (Input cables) of the driver. 2.
S couplers Series KK Page 59 Double layer tubing Series TRB/TRBU Page 69 P .00 Sealed construction for reduced leakage Inner tube Soft nylon polyurethane Exterior layer FR double layer tubing cross section e Correct tube cutting surface by using special tools.
Further, even in the case of types having an internal contact protection circuit (D-B54, D-B64, D-B59W, D-P70, D-P74), if the length of the wiring to the load is extremely long (30m or more) and a PLC having a large rush current is used, confirm whether a contact protection box may be necessary.
Model Wires[mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) (b) When using the 600V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire) Selection example of wire size when using HIV wires is indicated below.
(FR-RC-(H)()() [mm2] FR-RC-15K 14(AWG6) FR-RC-30K 14(AWG6) FR-RC-55K 22(AWG4) FR-RC-H15K 14(AWG6) FR-RC-H30K 14(AWG6) FR-RC-H55K 14(AWG6) (b) 600V (HIV ) HIV(FR-RC-(H) ()()(1)(a)IV 11.2 2(HIV) 2] (12) [mm L1L2L3 L11L21 UVW PC B1B2 BUBVBW OHS1OHS2 LECSS-S5 LECSS-S7 2(AWG14) 1.25(AWG16) 1.25(AWG16) 2(AWG14) 1.25(AWG16) LECSS-S8 1. (1)(c) 2. 11 21 11 (c) (1)(a)(b) (2) a FVD5.5
(FR-BSF01FR-BLF) 7) 8) 11 20 11.
Further, even in the case of types having an internal contact protection circuit (D-B54, D-B64, D-B59W, D-P70, D-P74), if the length of the wiring to the load is extremely long (30m or more) and a PLC having a large rush current is used, confirm whether a contact protection box may be necessary.
Table 1 Allowable shaft load Model Load direction Fr Fs [N] Fr [N] M [N-m] Fs CRB10 9.8 14.7 0.13 M CRB15 9.8 14.7 0.17 CRB20 19.6 24.5 0.33 CRB30 24.5 29.4 0.42 CRB40 40 60 1.02 Fig.1 Note) Application point of force "Fr" is at the center of longitudinal dimension of the key. (2) For better operating conditions it is recommended to use the method shown in the figure below to avoid applying
Table5 Allowable load N Size Load direction Fsa Fsa Fsb Fr Fr 10 15.7 7.8 14.7 15 19.6 9.8 19.6 20 49 29.4 49 30 98 49 78 40 108 59 98 Fsb Point of application of force of Fr is the center of shaft flat face and longer dimension of the key.
Table 2: Allowable Shaft Load N Model Fr Fs CRB2BW40 60 40 Note) Point of application of force Fr is the center to longitudinal dimension of key. 6 It is recommended to use the method in Figure 2 to avoid applying direct load to the shaft for better operating conditions.
Fsa Fsb M Fig. 2 Table 6 [N] [N] Load direction Size Size Load direction High Basic precision Fsa Fsb Fr M[Nm] Fsa Fsb Fr M[Nm] type type 10 78 74 78 2.4 10 107 74 86 2.9 20 137 137 147 4.0 20 197 137 166 4.8 30 363 197 196 5.3 30 398 197 233 6.4 50 451 296 314 9.7 50 517 296 378 12.0 70 476 296 333 12.0 100 708 493 390 18.0 200 1009 740 543 25.0 Flange application Table 7 shows L-dimension
Table 4 Allowable load N Load direction Size Fsa Fsb Fr 10 15.7 7.8 14.7 15 19.6 9.8 19.6 20 49 29.4 49 30 98 49 78 40 108 59 98 Fig.2 Load direction Point of application of force of Fr is the center of shaft flat face and longer dimension of the key.
Fsb Fsa Long shaft side Fr 1) Rubber bumper ... Kinetic energy is absorbed by placing an elastic body (rubber) at the end of the rotation. 2) Air cushion . The exhaust air is compressed shortly before the end of the rotation, and the load's kinetic energy is absorbed by its repulsive force.
Unit: N Load direction Fsb Model Fsa Fr Fsa Fsb CRB2BW, CRBU2W10 CRB2BW, CRBU2W15 CRB2BW, CRBU2W20 CRB2BW, CRBU2W30 CRB2BW, CRBU2W40 CRB1BW50 CRB1BW63 CRB1BW80 CRB1BW100 9.8 14.7 9.8 Fr Long-shaft side 9.8 14.7 9.8 19.6 24.5 19.6 24.5 29.4 24.5 40 60 40 196 245 196 Short-shaft side Short-shaft side Long-shaft side 340 390 340 490 490 490 539 588 539 99 Series CRB2/CRBU2/CRB1 Inertial Moment