SMC Corporation of America
Elite Part Number Search
Search Results "RDLQB32-75M-F-M9PWSAPC"

flats 17 Purge air discharge tubing port for dehumidification Applicable tube O.D.: 12 (NPT threads: 1/2 inch) Applicable tube O.D.: 10 (NPT threads: 3/8 inch) 26 Series IDG Membrane Air Dryer Dimensions (mm) (M Type) 1in = 25.4mm , , IDG60HM, 75HM, 100HM IDG60M, 75M, 100M (A) (B) Port size D (C) L Purge air for dew point indicator M J K N H G 37 22 18 OUT IN (F) (E) (352) Purge air for

Note 2) They are not applicable in case the thread type is N or F.

This is a legacy product, and replaced byCDG1UA32-50Z-M9PWSAPC, CYLINDER, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, LE, 32MM CG DBL-ACT AUTO-SW, 1.34625 lb

PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) b Set the stopper on the retainer while holding down the V-band outside perimeter, and then tighten the wing bolt to the prescribed position.

PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) b Set the stopper on the retainer while holding down the V-band outside perimeter, and then tighten the wing bolt to the prescribed position.

HEPO II element Absolute filtration accuracy: 2 to 13m US FDA compatible Nonwoven fabric element with high filtration accuracy of more than 99% removal and without fiber outflow and release of chemical components Material: PP (EJ102S ... x 0) PP depth element Nominal filtration accuracy: 1 to 75m Material: PP EJ202S ... x 11 (L125) EJ302S ... x 11 (L250) EJ402S ... x 11 (L500) Set the

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention)

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: w/By-Pass, Right-Hand Piping, Drop Prevention, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking), By-Pass Piping: R (w/By-Pass, Right-Hand Piping, Drop Prevention), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: M (Rod End Male Threads), Locking Direction: B (Retraction Locking), By-Pass Piping: None (Emergency Stop), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector), Number

Magnet: Built-in, Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Male Threads, Locking Direction: Extension Locking, By-Pass Piping: w/By-Pass, Right-Hand Piping, Drop Prevention, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: -, Number: -

LECYU uses the MECHATROLINK-III protocol, connecting up to 62 units at a max distance of 75m between units, with 100 Mbps transmission speed.  Synchronous motion control is possible with additional equipment.

LECYU uses the MECHATROLINK-III protocol, connecting up to 62 units at a max distance of 75m between units, with 100 Mbps transmission speed.  Synchronous motion control is possible with additional equipment.

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 100mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 25mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 75mm, Body Option: Rod End Female Threads, Standard, Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 20mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Magnet: D (Built-in), Mounting: B [Through Hole (Standard)], Bore Size: 32mm, Port Thread Type: Rc, Stroke: 40mm, Body Option: M (Rod End Male Threads), Locking Direction: F (Extension Locking)

Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.25~1,