Type: Pressure Sensor, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings, Plumbing Thread Type: -, Plumbing Thread Nominal: -, Fluid Characteristics: Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature Range
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: 01 [R 1/8(w/M5 Female)], Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: M5X0.8, Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: L (IO-Link/Switch: 1 output), Lead Wire Termination: S (With M12-4 pin connector, 500 mm)
Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: ±2%F.S., Port Size: R06 (Ø6 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: L (IO-Link/Switch: 1 output)
Type: Pressure Sensor, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings, Plumbing Thread Type: -, Plumbing Thread Nominal: -, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 1.5, Operating Temperature
For pressure sensor details, refer to the PSE540 series in the Web Catalog and the Operation Manual.
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 002 (0.2 MPa, −20 kPa, 20 kPa), OUT1 Hysteresis: 2 (0.02 MPa, 2 kPa, 2 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R06 (Ø6 Plug-In Reducer), Output Specification: P (PNP open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 4 (0.04 MPa, 4 kPa, 4 kPa)
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
PSE540 is UL/CSA, CE and RoHS compliant, with an IP40 enclosure. Smallest remote pressure sensor from SMC, for the most compact applications; Power supply requirement: 12 to 24 VDC; 1 to 5V analog output; 2 Accuracy options: ±1% or ±2% of F.S.; Repeatability: ±0.2% of F.S.; Port sizes: M3, M5, 1/8 Rc or NPT male; M5 female; ø4 or ø6mm plug for fittings
PSE540 is UL/CSA, CE and RoHS compliant, with an IP40 enclosure. Smallest remote pressure sensor from SMC, for the most compact applications; Power supply requirement: 12 to 24 VDC; 1 to 5V analog output; 2 Accuracy options: ±1% or ±2% of F.S.; Repeatability: ±0.2% of F.S.; Port sizes: M3, M5, 1/8 Rc or NPT male; M5 female; ø4 or ø6mm plug for fittings
PSE540 is a remote pressure sensor with an IO-Link or switch output. This sensor's construction optimizes space savings, for tight, constrained spaces. The rated pressure range is suitable for a standard pneumatic system. PSE sensors can measure pressure of any non-corrosive, non-flammable gas. 8 different port options offer tremendous adaptability to various applications.