Type: Pressure Sensor, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [Threads] Male thread, Plumbing Thread Type: M, Plumbing Thread Nominal: M5x0.8, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature Range
Pressure: For Compound Pressure (-101~101kPa), Port Size: R06 Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: 3 (For Compound Pressure (-101~101kPa)), Port Size: R07 (1/4" Reducer Type), Option: L (Sensor Cable)
Pressure: For Compound Pressure (-101~101kPa), Port Size: 1/4" Reducer Type, Option: CL [Sensor Cable/Connector (PSE300) 1 pc.]
Type: Pressure Sensor, Fluid Type: Air, Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: [One-Touch Couplings] One-Touch Couplings, Plumbing Thread Type: -, Plumbing Thread Nominal: -, Fluid Characteristics: Noncorrosive / Incombustible, Pressure Resistance(MPa): 0.5, Operating Temperature
Pressure: 0 [Positive Pressure (0~1MPa)], Port Size: 1/4" Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: For Low Pressure (0~101kPa), Port Size: 1/4" Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Pressure: For Vacuum (0~101kPa), Port Size: 1/4" Reducer Type, Option: C2L [Connector for Pressure Sensor Controller (1pc)+Sensor Cable (3m)]
Power connector
Pressure Sensor/Sensor Range ZSM Sensor supply pressure 101 to 101 kPa (Compound pressure) (Vacuum) (Low pressure) (High pressure) PF2 PSE533 10 to 101 kPa 10 to 101 kPa 0.1 to 1 MPa Regulating pressure range PSE531 PSE532 PSE530 Applicable pressure sensor IF SET If the controller is equipped with a unit switching function, unit setting can be changed.
Pressure sensor/Sensor range Sensor supply pressure (Compound pressure) (Vacuum) (Low pressure) (High pressure) 101 to 101kPa PSE533 10 to 101kPa 10 to 101kPa 0.1 to 1MPa Regulating pressure range PSE531 PSE532 PSE530 Applicable pressure sensor SET If the controller is equipped with a unit switching function, unit setting can be changed.
Pressure Sensor/Sensor Range ZSM Sensor supply pressure 101 to 101 kPa (Compound pressure) (Vacuum) (Low pressure) (High pressure) PF2 PSE533 10 to 101 kPa 10 to 101 kPa 0.1 to 1 MPa Regulating pressure range PSE531 PSE532 PSE530 Applicable pressure sensor IF SET If the controller is equipped with a unit switching function, unit setting can be changed.
Pressure sensor/Sensor range Sensor supply pressure (Compound pressure) (Vacuum) (Low pressure) (High pressure) 101 to 101kPa PSE533 10 to 101kPa 10 to 101kPa 0.1 to 1MPa Regulating pressure range PSE531 PSE532 PSE530 Applicable pressure sensor SET If the controller is equipped with a unit switching function, unit setting can be changed.
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
PSE531 and PSE533 are remote vacuum sensors with a 1 to 5V analog signal output. 531 is for low vacuum range of -101 to 0 kPa, while PSE533 is for compound pressure from -101 to 101 kPa. PSE sensors can monitor any non-corrosive, non-flammable gas. The accuracy and environmental capabilities are suitable for general purpose applications.
PSE531 and PSE533 are remote vacuum sensors with a 1 to 5V analog signal output. 531 is for low vacuum range of -101 to 0 kPa, while PSE533 is for compound pressure from -101 to 101 kPa. PSE sensors can monitor any non-corrosive, non-flammable gas. The accuracy and environmental capabilities are suitable for general purpose applications.
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
Piping specifications Lead wire length R06 R07 6 reducer 1/4" reducer L 3 m Switch Specifications PS1000/PS1100 PS1200 58 (0.4) 0 psi (MPa) psi (kPa) 29 (0.2) 7.25 (50) Set pressure Set pressure 0 14.5 (100) t t 14.5 (0.1) The switch turns ON when the set pressure is reached or exceeded. The switch turns ON when at the set pressure or below.
Caution PS 10 00 R06 L Port size R06: 6 reducer, R07: 1/4 reducer OFF Do not touch the terminals and connectors while the power is on. Otherwise electric shock, malfunction or damage to the product can result.
109No.PS-OMW0012-C Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533