Your search for PFM returned 30 result(s)
There were no hits with the full part number, but there were 13 hits in the keyword search.
There were no hits with the full part number, but there were 9 hits in the keyword search.
Product Information » New Products Search Results
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: V (Panel Mount Adapter for w/
Flow Rate Range: 50 [1 to 50 (25 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure If setting is not necessary press the and buttons simultaneously for 1 second or longer. -34No.PS-OMS0007-H [F 6] Fine adjustment of display value This function is to manually perform a fine adjustment of the displayed pressure value.
-100.0~100.0 kPa T 2 X NPN2 Y PNP2 R NPN2+1 T PNP2+1 A1 A S NPN2+1 V PNP2+1 1: A2 B M SI3 P psi2 2 3 kPaMpa B D + M5 M5 1 01 R1/8 N01 NPT1/8 C4H 4mm J (2m) C6H 6mm N7H 1/4 inch C4L 4mm C6L 6mm N7L 1/4 inch -8No.PS-OMU0002CN-D / A ZS-46-A1 38L(2 ) B ZS-46-A2 38L(2 ) ZS-46-B + ZS-46-D ZS-46-5L 5 2m ZS-27-01 R1/8 ZS-46-N1 NPT1/8 ZS-46-N2 4mm ZS-46-C4H 6mm ZS-46-C6H 1/4 inch
Suction Verification High Vacuum Suction Work 1 Work 2 Work n Max. A Formula for Obtaining the Set-Value P-1 P_1 or P_2 H_1 or H_2 H-1 P_1 (P_2) = A (A-B)/4 n_1 (n_2) = B + (A-B)/4 H_1 (H_2) = (A-B)/2 n-1 Min.
Suction Verification High Vacuum Suction Work 1 Work 2 Work n Max. A Formula for Obtaining the Set-Value P-1 P_1 or P_2 H_1 or H_2 H-1 P_1 (P_2) = A (A-B)/4 n_1 (n_2) = B + (A-B)/4 H_1 (H_2) = | (A-B)/2| n-1 Min.
OUT1 [AP1 RUn] (A2L RUn 1 ) , P_1=A-(A-B)/4 n_1=B+(A-B)/4 A= H_1=(A-B)/2 H_1=(A-B)/2 B= 1 -34No.PS-OMS0006CN-G [F 6] 5R.D. <> [F 6] [F 6] -35No.PS-OMS0006CN-G [F10] <> [F10] OFF 2 OUT1 [dUAL]2 [dUAL]2 () () 37 () () () 37 () [F10] -36No.PS-OMS0006CN-G <> (OFF) [F10 ] OUT1 OUT1 OFF n_1 () [F10 ] OUT1 OUT1 OUT1 n1H n1L 2 2 ( ) OUT1 OUT1 ( ) OUT1 () ( ) OUT1 (
The set values for OUT1 are displayed in auto-preset mode as follows: Normal output Reversed output P_1 = A-(A-B)/4 n_1 = B+(A-B)/4 A = Max. pressure H_1 = (A-B)/2 H_1 = (A-B)/2 B = Min. pressure The set values of OUT2 become as follows "_", i.e. "P_2", "n_2", "H_2".
3 ISE30A -0.11 MPa Y ZSE30A 0-101 kPa ZSE30AF -100100 kPa K T 2 01 R1/8(M5) N01 NPT1/8 (M5) A1 A C4H 4mm5/32 inch C6H 6mm A2 B NH7 1/4 inch N7H A3 C C4L 4mm5/32 inch C6L 6mm B N7L 1/4 inch D + N NPN1 P PNP1 A NPN2 B PNP2 C NPN1+ D NPN1+ E PNP1+ F PNP1+ 1 L (2 m) 1 (2 m 1 G 1 M SI2 P (psi)1 1NP3 4 1 2kPaMPa -8No.PS-OML0002CN-G / A ZS-38-A1 (M35 L 2 ) B ZS-38-A2 (M35 L
Applicable for pressure detection with a wide range of fluids, by using a stainless steel diaphragm. 16-2-25 2 Pressure detection for a wide range of fluids.
Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.
Note 2) When voltage output is selected, a simultaneous selection of switch output and current output is not available. Note 3) When current output is selected, a simultaneous selection of switch output and voltage output is not available.
1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT X694 IN OUT 73 X731 (Ar)(CO2) (ArCO2) 92:890:1080:2070:3060:40 75 / ZS-33-D 2 m () ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () 2 ZS-33-MS () 3 ZS-33-R DIN 1 2 3 4 5 DIN F02(G1/4)DIN -12No.PF-OMJ0005CN-I LED UP) (DOWN) (OUT2) (OUT1) SET) (OUT ) (IN ) (OUT1
Flow Rate Range: 11 [2 to 100 (50 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: 2 NPN Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: ø1/4 One-touch Fitting, Piping Entry Direction: Bottom Side, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector