SMC Corporation of America
Elite Part Number Search
Search Results "PFM511-C8L-2-A-R"

Model Max. rated flow Model Max. rated flow [L/min] [L/min] PFM510--1 10 (5) PFM510--2 10 (5) PFM525--1 25 (12.5) PFM525--2 25 (12.5) PFM550--1 50 (25) PFM550--2 50 (25) PFM511--1 100 (50) PFM511--2 100 (50) : ( ): Fluid: CO2 : ( ): Fluid: CO2 -55No.PF-OMJ0018-F Dimensions PFM3 Panel cut-out dimensions Panel thickness: 0.5 to 6.0 mm Individual Two or more in a row (n: The number of products

B C R V Q C B IN OUT IN OUT 2 x P (Port size) 2 x P (Port size) Clearance for maintenance G AC-A A Clearance for maintenance G AC-B Bracket (Option) AL30-A to AL40-06-A AL50-A AL60-A N T J M U J N T U M S S D R R C B V Q B C V Q IN OUT IN OUT Bracket (Option) 2 x P (Port size) A E Clearance for maintenance G 2 x P (Port size) Clearance for maintenance G A Applicable model AL10-A/AL20-A AL30

+ 0.77 (n: stations) Rc3/8 Rc1/2 Rc1/2 Rc3/4 22 Series VQ7-8 DIN Connector Type VV72-142 118 142 118 9 2n-Rc3/8, 1/2 67 20 Indicator light 14 34 9 (4-Rc1/8) Port P, R1, R2 for Rc3/4 only U side U side 18 Manual override 23 R4.5 R4.5 P= 56 60 (73) 60 (73) P= 56 B B B B B 14 42 18 13 13 A B SMC SMC SMC B B B A A A A A PA PA PA A B A B L1 L2 L1 L2 A B SMC PA A B PA L side R side L side R side

Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.

Circuit (Class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.

1 W Z (2 m) (2 m) + () 2 R S () () T V () () A A B B -11No.PF-OMJ0005CN-I IN OUT X693 IN OUT 73 IN OUT X694 IN OUT 73 X731 (Ar)(CO2) (ArCO2) 92:890:1080:2070:3060:40 75 / ZS-33-D 2 m () ZS-33-F ZS-33-J () ZS-33-JS () ZS-33-M () 2 ZS-33-MS () 3 ZS-33-R DIN 1 2 3 4 5 DIN F02(G1/4)DIN -12No.PF-OMJ0005CN-I LED UP) (DOWN) (OUT2) (OUT1) SET) (OUT ) (IN ) (OUT1

7 A*8 201 2~200L/min 8 2 (11) S () C8 8(5/16") *6 02*1 Rc1/4 M SI*7 N02*1 NPT1/4 6 F02*1 G1/4*2 SI 1 2ISO1179-1 7:L/min :L 1 (11) L*3 3 OUT1 OU2 A NPN NPN B PNP PNP C NPN (1~5V) D NPN (4~20mA) E*4 PNP (1~5V) F*4 PNP (4~20mA) G*4 NPN *5 H*4 PNP *5 4 5 -10No.PF-OMO0004CN-E 1 W N (2 m) (2 m) + () 2 R S () () T V () () -11No.PF-OMO0004CN-E / ZS-33-D 2m ZS-33-F ZS-33-J (

Circuit (class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The product is a approved product only if it has a mark on the body. [A ir ] dry air, N2 [FLU] Operating fluid [F 3] Check that the above preparation has been performed correctly, then part A shown should be pressed in by hand to make temporary connection.

Piping port 3 8 03 04 06 1 2 3 4 3-5-79 80 Series VFR5000 Construction 2 position single 2 position double VFR520 VFR510 (B) (A) 4 2 (B) (A) 4 2 (EA)(P)(EB) 5 1 3 (EA)(P)(EB) 5 1 3 r u e t r u q o e !

18 42 14 VZ SMC SMC SMC B A VF A PA B PA VFR B A A VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B PA L1 L2 VZS B A A A VFS B SMC VS4 4n-3/8, 1/2 A B VQ7 EVS A PA R side L side 40(53) VFN D side (2n-1/8) 2 82.5 62 59 17 154 (Single) 175.5 (Double) 180.5 175.5

Solenoid Valve: Size 2 Metal Seal/Rubber Seal Series VQ7-8 Pre-wired Connector Type VV72-67 9 118 142 20 2-1/8 P , R1, R2 port for Rc 3/4 U side Indicator light 18 23 R4.5 P = 56 60 (73) VK Manual override B PA 18 42 14 VZ SMC SMC SMC B A VF A PA B PA VFR B A A VP4 B PA L1 L2 VZS B A A A VFS B SMC VS4 4n-3/8, 1/2 A B VQ7 EVS A PA R side L side 40(53) VFN D side (2n-1/8) 2 82.5 62 59 17 154

A B A B A B A B AXT511 -3 (V) AXT511 -4 (V) 24V DC 12V DC AXT511 -1 (V) AXT511 -2 (V) 100V AC 50/60 Hz 200V AC 50/60 Hz 0.049/0.043 0.024/0.021 0.031/0.020 0.015/0.01 VQ Rated voltage (V) Inrush current (A) Holding current (A) Allowable voltage (V) 0.075 0.15 VQ4 85 to 110% of rated voltage Insulation Class B (130 oC) or equivalent VQ5 A: With 2-M4 X 46 bolts for 2 position valve, B: With

VFS Y 5 3 37 25 22 14 1 VS4 25 25 3/8-2 port 3, 5 port 1/4, 3/8 1 port 9 1/4, 3/8-2 port 2, 4 port 1/8 12 port 1/8 14 port VQ7 VV71-(M Connector type) EVS VFN 100 80 100 80 37 23 U-side 9 2n-1/4, 3/8 14 9 U-side 15 PE port Indicator light Manual override R 4.5 R 4.5 53.5 53.5 9 9 38 9 B B 20 14 12 P = 43 A P = 43 PA 23 A A B B 14 12 A PA PA L1 L2 L2 L1 B B B 14 12 A A A A B 14 A A PA B B

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Z (w/o Lead Wire w/Connector), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33

Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: C8 (ø8 (5/16") one-touch fitting), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment