Your search for PFM returned 30 result(s)
There were no hits with the full part number, but there were 13 hits in the keyword search.
There were no hits with the full part number, but there were 9 hits in the keyword search.
Product Information » New Products Search Results
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover]
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: R (Bracket for w/o Flow Adjustment Valve: ZS-33-M
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: R (Bracket for w/o Flow Adjustment
25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon or carbon dioxide. 2-color display flow switch., Sensor and monitor separation, which allows remote monitors' centralization., Integrated flow adjustment valve as an option, reducing piping and saving space (unique feature in the market)., Operation indication also on the sensor., Fast response: either 50 ms, 0.5s, 1,
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -
or 2s can be chosen., Easy connection and removal of wiring., DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CB, IFW/PFW 1/8INCH PT VERSION, .88184 lb, ModelPort sizeMaterialSensor cableMassWith sensor cableWithout sensor cable01R 1/8M5 x 0.8Case: C3604 + nickel plated, Piping port/pressure sensor: Stainless steel 316LPSE56 - : Oil proof heavy-duty vinyl cable with
Model Max. rated flow Model Max. rated flow [L/min] [L/min] PFM510--1 10 (5) PFM510--2 10 (5) PFM525--1 25 (12.5) PFM525--2 25 (12.5) PFM550--1 50 (25) PFM550--2 50 (25) PFM511--1 100 (50) PFM511--2 100 (50) : ( ): Fluid: CO2 : ( ): Fluid: CO2 -55No.PF-OMJ0018-F Dimensions PFM3 Panel cut-out dimensions Panel thickness: 0.5 to 6.0 mm Individual Two or more in a row (n: The number of products
The product is a approved product only if it has a mark on the body. [A ir ] dry air, N2 [FLU] Operating fluid [F 3] Check that the above preparation has been performed correctly, then part A shown should be pressed in by hand to make temporary connection. Part A should then be pressed in using a suitable tool, such as pliers.
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: None, Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)]
(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2, Number of Outputs: 1, Analog Voltage Output(V): [DC1-5V] 1-5V, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Pipe Connection Direction: 2-way, Connecting Tube Diameter: -, Liquid contact parts material: Resin + Metal, Mounting Hole: Presence,