SMC Corporation of America
Elite Part Number Search
Search Results "PF3W520-F03-1-GAZ"

Examples of Internal Circuit and Wiring 1 to 5 V / 4 to 20 mA output type With temperature sensor 1 to 5 V output type PF3W5--1/2 PF3W5--1T Analogue output 1 to 5 V Analogue output 1 to 5 V Output impedance: 1 k Output impedance: 1 k Analogue output 4 to 20 mA Maximum load impedance Power supply voltage 12 V: 300 Power supply voltage 24 V: 600 -22No.PF-OMN0010-J Flow Measurement Measurement

11/4 14 11/2 / OUT1 OUT2 1 1~5 V 2 4~20 mA 1T 1~5 V 1~5 V (PF3W3)1~5V (-1-1T) 4~20mA(47) -11No.PF-OMN0009CN-F PVC PF3W5 U 48 () 3 A : 11 21 10~100 L/min 30~250 L/min U PVC 2 11 21 R (PVC) 11 21 40 11 21 25 25A 30 30A 250L/min G : SI : G : 1[L/min]=0.2642[gal/min] 1[gal/min]=3.785[L/min] L/min L/min(gal/min) JIS K6742 1 2 1~5 V 4~20 mA (PF3W3) 1~5(1) 1 N M8(3m) -12No.PF-OMN0009CN-F

For example, when analogue output is 1 to 5 V, F.S. = 5[V] 1[V] = 4[V], (ref. 1%F.S. = 4[V] x 1% = 0.04[V]) F.S. (Full span, Full scale) H A function to store the accumulated flow value in the products internal memory. The flow value will be stored at a set time interval of either 2 or 5 minutes.

1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/

Type Symbol sensor Flow rate Flow rate Temp. 1 Analogue 1 to 5 V None 2 Analogue 4 to 20 mA Remote sensor 1T Analogue 1 to 5 V Analogue 1 to 5 V With temp. sensor 2T 1 Analogue 4 to 20 mA Analogue 4 to 20 mA A NPN NPN B PNP PNP C NPN Analogue 1 to 5 V D NPN Analogue 4 to 20 mA None E PNP Analogue 1 to 5 V F PNP Analogue 4 to 20 mA G 1 NPN External input 2 Integrated display type H 1 PNP External

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V)

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: -, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -

50 12.5 Y-05MNote 1) 64 16.5 Y-08MNote 1) 80 23.5 Y-10MNote 1) 80 23.5 Y-12MNote 2) 119 28.5 Note 1) A pin, cotter pin and a flat washer are equipped as standard.

kPa 10 to 105 kPa 0.001 0.1 0.001 0.001 0.01 PSE564 PSE574 0 to 500 kPa 50 to 525 kPa 0.001 1 0.01 0.01 0.1 PSE530 PSE540 PSE560 PSE570 0 to 1 MPa 0.105 to 1.05 MPa 0.001 1 0.01 0.01 0.1 PSE575 0 to 2 MPa 0.105 to 2.1 MPa 0.001 1 0.01 0.01 0.2 PSE576 0 to 5 MPa 0.25 to 5.25 MPa 0.01 0.1 0.1 1 PSE577 0 to 10 MPa 0.5 to 10.5 MPa 0.01 0.1 0.1 1 0 to 1.6 MPa 0.105 to 1.68 MPa 0.001 1 0.01

relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 JIS B 8433-1993: 2) : : : 1. 2. 3. 1. 2. 3. 4

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: G, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration Certificate: None

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

FLOW Hysteresis 1 Hysteresis 1 SET Set point 1 Set point 2 button (UP) button (DOWN) button (SET) ON Item Default settings Model Item Default setting Instantaneous flow PF2A2 series [10L] 1 to 10 L/min type (PF2A510) Connecting the wiring Attaching the sensor connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.

Metric size Inch size 3 4 5 6 1/8 standard 1/4 standard 3/8 standard 1/2 standard 07 09 11 13 06 08 10 12 1/4" 5/16" 3/8" 1/2" 6 8 10 12 Type Port size 3 Universal Symbol 01 02 03 04 F02 F03 F04 N01 N02 N03 N04 Pilot port M5 x 0.8 Rc 1/8 Rc 1/8 Rc 1/4 G 1/8 G 1/8 G 1/4 10-32 UNF NPT 1/8 NPT 1/8 NPT 1/4 Cylinder side R 1/8 R 1/4 R 3/8 R 1/2 R 1/4 R 3/8 R 1/2 NPT 1/8 NPT 1/4 NPT 3/8 NPT 1/2