SMC Corporation of America
Elite Part Number Search
Search Results "PF3W511-U25-2-GR"

N M8 M8 R / ZS-40-K PF3W504/520 4 3X8 ZS-40-L PF3W540 4 3X8 ZS-40-M PF3W511 4 4X10 M8 ZS-40-A 3 m 2 250 L/min PVC 25 A ZS-40-U25 25 A PVC 1 PVC 30 A ZS-40-U30 30 A PVC 1 25 A ZS-40-U25-A 1 M5x80 2 30 A ZS-40-U30-A 1 M5x65 2 PVC 1~2% -13No.PF-OMN0009CN-F FLOW POWER (OUT ) M8 1 DC+ (4 ) () 2 NC/ () () 3 DC() 4 (IN ) () M8 IN OUT POWER FLOW POWER FLOW -14No.PF-OMN0009CN-F

The 25A- series variations are compatible with secondary battery manufacturing for electronics, automotive, and other vehicle types.  25A-PF3W511-U25 is a digital flow sensor that constantly monitors water or coolant flow.  The -U variation features PVC piping for additional compatibility with deionized water and liquid chemicals. 

Grease pack part number: GR-S-010 (10 g) 492 Series CUW Free Mount Cylinder Double Acting, Double Rod Dimensions: Double Acting, Double Rod 6, 10 2 x P through Rod end nut 2 x M5 x 0.8 2 x NN Auto switch 2 x P through 4 x T counterbore W + Stroke S + Stroke Z + 2 x Stroke 16 to 32 2 x M5 x 0.8 (32: Rc 1/8) 2 x P through Rod end nut CUJ Rod End Nut/Accessory CU CQS 2 x NN CQ2 Auto switch RQ

3 0 1.3 1.06 2.19 3/8-18 1 3/8 2.13 3 3/4 2.48 5 1/4 1 1 1/4 2 3/8 2 5/16 3/4-16 7/8 3/8 3/8 19/32 325 (3.25) 1 5/8 3.9 2 1 1/2 5/8 1 1/4 3/8-24 3 3/4 0 1.57 1.18 2.76 1/2-13 1 5/8 2.59 4 1/4 2.72 6 5/64 1 3/8 1 1/2 2 5/8 2 11/16 1-14 1/2 5/8 5/8 400 (4) 1 3/8 1 5/8 4.7 2 1 1/2 5/8 1 1/4 3/8-24 4 1/2 0 1.57 1.18 3.32 1/2-13 1 5/8 2.59 4 1/4 2.72 6 5/64 2 1/10 2 5/8 2 11/16 1-14 1/2 5/8 5/

Rated Flow Range: 11 (10 to 100 L/min), Port, PVC Pipe O.D.: 25 (Port Size: 25A, Pipe O.D.: 32mm), Output Specification: 1 (OUT1: Analog 1 to 5V), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)

Rated Flow Range: 10 to 100 L/min, Port, PVC Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -

Rated Flow Range: 10 to 100 L/min, Port, PVC Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: Analog 4 to 20mA, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -

Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. Insufficient supply voltage may not drive a load due to a voltage drop inside the product.

.: 32mm), Output Specification: 2 (OUT1: Analog 4 to 20mA), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket)

Rated Flow Range: 10 to 100 L/min, Port, PVC Pipe O.D.: Port Size: 25A, Pipe O.D.: 32mm, Output Specification: OUT1: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: Bracket, Calibration Certificate: -

1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/

If the error cannot be reset after the above measures are taken, then please contact SMC. 3 1 1 DC(+): Brown 4 2 2 NC / Analogue output (temperature): White Refer to the SMC website (URL http://www.smcworld.com) for more detailed information about product troubleshooting. 3 DC(-): Blue Pin number of the connector at the cable side Direct mounting (PF3W511) Mount using the self tapping screws