Find the terms of Equation (13.1) from the diagram. 5 0.1 [mA] Ig1 20 1000 5 0.1 [mA] Ig2 20 1000 Ign 0 (not used) Iga 0.1 [mA] Igm 0.1 [mA] Insert these values in Equation (13.1). Ig 10 {0.1 0 0.1 1 (0.1 0.1)} 4.0 [mA] According to the result of calculation, use a leakage current breaker having the rated sensitivity current (Ig) of 4.0[mA] or more.

/min** 1900 ln/min** 1000 ln/min** 1900 ln/min* 400 ln/min* Port Size (IN, OUT) 38 12 38 12 14 EXH Port Size 12 14 38 38 12 INSTALLATION Pilot EXH Port Size 18 The Booster Regulator should be installed with its piston in a horizontal position.

(Voltage input: 1 to 5 V/Current input: 4 to 20 mA) Pressure switch/Flow switch can be displayed. B A is displayed for 1 V (or 4 mA). B is displayed for 5 V (or 20 mA). The range can be set as required. Display Select NPN or PNP A NPN PNP Voltage input 1 V 5 V Current input 4 mA 20 mA Analog output of 0 to 10 V is also available.

Switch operation Normal or reversed output Maximum load current 80 mA Maximum applied voltage (Only NPN) 28 VDC Switch output Internal voltage drop (Residual voltage) NPN output type: 1 V or less (at load current of 80 mA) PNP output type: 2 V or less (at load current of 80 mA) Response time 8 Select from 1 s, 2 s, 5 s.

Item PF3A703H PF3A706H PF3A712H The operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance.

Over current error The switch output load current is 80 mA or more. [Measurement mode] Measurement mode is the condition where the flow is detected and displayed, and the switch function is operating. This is the basic mode; other modes should be selected for set-point changes and other function settings.

Large Flow Capacity Base Mounted Without Subplate M3 With Subplate V O LTA G E 5 24 VDC 6 12 VDC V 6 VDC S 5 VDC R 3 VDC 1 100 VAC 50/60 Hz 3 110 VAC 50/60 Hz 115 VAC 50/60 Hz 2 200 VAC 50/60 Hz 4 220 VAC 50/60 Hz 230 VAC 50/60 Hz E L E C T R I C A L E N T R Y M A N U A L O V E R R I D E G Grommett (Lead Wire Length: 300mm) H Grommett (Lead Wire Length: 600mm) L L Type Plug with Lead Wire LN

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector)

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: -, Calibration Certificate: -

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only)

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: -

Auto Drain Float Type Model NAD600-N10 Minimum operating pressure 45psi. Maximum operating pressure 145psi. 1 NPT top entry. (N10), 3/4 NPT (N06) Model NAD402-N04 (N04 = 1/2 NPT) Minimum operating pressure 22psi. Maximum operating pressure 145psi.

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector), Unit Specification: M (SI Unit Only), Calibration Certificate: A (Made to Order)

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: PNP; Func: Analog Voltage Ouput <-> External Input, Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: SI Unit Only, Calibration Certificate: Made to Order

Rated Flow Range: 30 to 3000 l/min, Thread Type: NPT, Port Size: 1, Output Specifications: Out: NPN; Func: Analog Current Output <-> External Input, Lead Wire: w/o Lead Wire and M12 Connector, Unit Specification: SI Unit Only, Calibration Certificate: Made to Order

Ig1 = 20 5 1000 = 0.1 [mA] Ig2 = 20 5 1000 = 0.1 [mA] Ign = 0 (not used) Iga = 0.1 [mA] Igm = 0.1 [mA] Insert these values in equation (11.1). Ig 10 {0.1 + 0 + 0.1 + 1 (0.1 + 0.1)} 4 [mA] According to the result of calculation, use an earth-leakage current breaker having the rated sensitivity current (Ig) of 4.0 mA or more.

3 metre LED 24v DC 100v AC 200v AC 550 mA 525 mA 512.5 mA 2 wire Tie rod mount reed Grommet DA54L 3 metre LED 2 wire Band mount reed Grommet DB53L 24v DC 550mA 3 metre LED 24v DC 100v AC 200v AC 550 mA 5-25 mA 512.5 mA 2 wire Band mount reed Grommet DB54L 3 metre LED 3 wire Solid state NPN tie rod Grommet DF59L 5, 12, 24v DC 28v DC or less 40 mA or less 3 metre LED 3 wire Solid state PNP

Ig1 = 20 5 1000 = 0.1 [mA] Ig2 = 20 5 1000 = 0.1 [mA] Ign = 0 (not used) Iga = 0.1 [mA] Igm = 0.1 [mA] Insert these values in equation (11.1). Ig 10 {0.1 + 0 + 0.1 + 1 (0.1 + 0.1)} 4 [mA] According to the result of calculation, use an earth-leakage current breaker having the rated sensitivity current (Ig) of 4.0 mA or more.

Ig1 = 20 5 1000 = 0.1 [mA] Ig2 = 20 5 1000 = 0.1 [mA] Ign = 0 (not used) Iga = 0.1 [mA] Igm = 0.1 [mA] Insert these values in equation (11.1). Ig 10 {0.1 + 0 + 0.1 + 1 (0.1 + 0.1)} 4 [mA] According to the result of calculation, use an earth-leakage current breaker having the rated sensitivity current (Ig) of 4.0 mA or more.