Before Use Digital Flow Switch PF3A703H/PF3A706H/PF3A712H-L Use the correct tightening torque for piping. (Refer to the table below for the required torque values.) If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the fittings may become loose. Avoid any sealing tape getting inside the fluid passage.
Flow switch flow setting and functions PF3A703H/PF3A706H/PF3A712H IO-Link function PF3A703H/PF3A706H/PF3A712H-L Function selection mode In this mode, each function setting can be changed separately. In measurement mode, press the S button for 3 seconds or longer to display [F 0]. Press the or button to select the function to be changed.
. -24No.PF-OMU0007-D Flow specification when [Ft] is selected by the units selection function Model PFG3#0 Model PFMB7201 PFMB7501 PFMB7102 PFMC7102 PFMB7202 PFMC7202 PF3A703H PF3A706H PF3A712H SMC Flow Applicable Switch PFMC7501 Rated flow range 0.08 to 7.06 cfm 0.2 to 17.7 cfm 0.4 to 35.3 cfm 0.8 to 70.6 cfm 1.1 to 105.9 cfm 2.2 to 211.9 cfm 4.5 to 423.8 cfm Instantaneous flow -0.36 to
1 270 (15) NAN300-N03 84 25 22 NAN700-N12 114 440 (24) NAN400-N04 92 30 27 NAN800-N14 112 590 (33) NAN500-N06 107 46 36 NAN900-N20 2 960 (53) NAN600-N10 132 50 41 Note: When ordering PT Ports, remove (N) from Model Number Eg: AN200-02 NAN700-N12 200 74 55 NAN800-N14 233 74 60 NAN900-N20 263 86 70 Courtesy of Steven Engineering, Inc. !
1 270 (15) NAN300-N03 84 25 22 NAN700-N12 114 440 (24) NAN400-N04 92 30 27 NAN800-N14 112 590 (33) NAN500-N06 107 46 36 NAN900-N20 2 960 (53) NAN600-N10 132 50 41 Note: When ordering PT Ports, remove (N) from Model Number Eg: AN200-02 NAN700-N12 200 74 55 NAN800-N14 233 74 60 NAN900-N20 263 86 70 Courtesy of Steven Engineering, Inc. !
Auto Drain Float Type Model NAD600-N10 Minimum operating pressure 45psi. Maximum operating pressure 145psi. 1 NPT top entry. (N10), 3/4 NPT (N06) Model NAD402-N04 (N04 = 1/2 NPT) Minimum operating pressure 22psi. Maximum operating pressure 145psi.
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: ES (Out: PNP; Func: Analog Voltage Ouput <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: FS (Out: PNP; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: DS (Out: NPN; Func: Analog Current Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specifications: CS (Out: NPN; Func: Analog Voltage Output <-> External Input), Lead Wire: N (w/o Lead Wire and M12 Connector)
DIGITAL FLOW SWITCH, PFA, DIGITAL FLOW SWITCH, 0.00000 lb
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series]
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None]
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L [Out: IO-Link, Switch Output (N/P); Func: None; Monitor Unit Model: None], Lead Wire: N (w/o Lead Wire and M12 Connector)
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series]
Rated Flow Range: 03 (30 to 3000 l/min), Thread Type: N (NPT), Port Size: 10 (1), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: N (w/o Lead Wire and M12 Connector)