SMC Corporation of America
Elite Part Number Search
Search Results "PF2W540-06N-1"

1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/

to 186 1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x

(mm) 4 6 8 4 6 8 1(P) 1(P) 1(P): Male thread 2(A): One-touch fitting Applicable tubing O.D. (mm) 1 8 4 Port size R Connection thread R Applicable tubing O.D.

Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: N (w/o Lead Wire)

Specifications PF2A511--1 PF2A200/201 PF2A551--1 Model Applicable flow rate sensor PF2A510--1 PF2A550--1 PF2A521--1 0.5 to 10.5 l/min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min Flow rate measurement range Note 1) 0.5 to 10.5 l/min 2.5 to 52.5 l/min 5 to 105 l/min 10 to 210 l/min 25 to 525 l/min Set flow rate range Note 1) 0.1 l/min 0.5 l/min 1 l/min 2 l/min 5 l/min Minimum

Output impedance: 1 k 3 DC(-) Piping port (OUT side) 4 Output for PF2A3 / PF2W3 1: Refer to the PF2A3 /PF2W3 operation manual for details of the flow monitor.

FLOW Hysteresis 1 Hysteresis 1 SET Set point 1 Set point 2 button (UP) button (DOWN) button (SET) ON Item Default settings Model Item Default setting Instantaneous flow PF2A2 series [10L] 1 to 10 L/min type (PF2A510) Connecting the wiring Attaching the sensor connector to the sensor wire Strip the sensor wire as shown. Do not cut the insulator.

Hysteresis mode 2 Panel Item Default settings Model button (UP) Panel mount adapter Item Default setting ( ) PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Indicator LED (OUT1) Set point 1 Set point 2 Hysteresis 1 Hysteresis 1 50% of max. rated flow [n_1] Input of the Set point 1 (OUT1) PF2A31 series [11L] 10 to 100 L/min type (PF2A511) button (SET) ON 50% of max. rated flow [n_2] Input

Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 06 (3/4), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 5~40 l/min, Thread: Rc, Port Size: 3/4, Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (4~20mA)

Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 1 (PNP Open Collector 2 Outputs)

Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 1 (PNP Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)

This is a legacy product, and replaced byVG342R-5DZ-06N

Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 0 (NPN Open Collector 2 Outputs)

Flow Range: 0 (PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40), Output Specification: 0 (NPN Open Collector 2 Outputs), Unit: M (S1 Fixed Unit)

Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: NPN Open Collector 2 Outputs, Unit: -

Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: NPN Open Collector 2 Outputs, Unit: S1 Fixed Unit

Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: PNP Open Collector 2 Outputs, Unit: -

Flow Range: PF2W504: 0.5~4, PF2W520: 2~16, PF2W540: 5~40, Output Specification: PNP Open Collector 2 Outputs, Unit: S1 Fixed Unit