Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 1 (Pulse Output + Analog Output (1~5V))

Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: 3m Lead Wire w/Connector, Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 5~40 l/min, Thread: Rc, Port Size: 1/2, Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)

Flow Range: 5~40 l/min, Thread: Rc, Port Size: 1/2, Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (4~20mA)

Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: N (w/o Lead Wire)

Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: N (w/o Lead Wire), Output Specification: 2 (Pulse Output + Analog Output (4~20mA))

Flow Range: 40 (5~40 l/min), Thread: Rc, Port Size: 04 (1/2), Wiring Specification: N (w/o Lead Wire), Output Specification: 1 (Pulse Output + Analog Output (1~5V))

Flow Range: 5~40 l/min, Thread: Rc, Port Size: 1/2, Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (4~20mA)

Flow Range: 5~40 l/min, Thread: Rc, Port Size: 1/2, Wiring Specification: w/o Lead Wire, Output Specification: Pulse Output + Analog Output (1~5V)

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.63907 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SW, REMOTE SENSOR, INSTRUMENTATION, IFW/PFW FLOW SWITCH, FA, IFW/PFW 1/2INCH PT VERSION, 1.59835 lb, ModelMeasured fluidDetection typeRated flow rangeOperating pressure rangeWithstand pressureOperating fluid temperatureLinearity Note 1)Repeatability Note 1)Temperature characteristicsOutput

SMC offers a variety of digital flow switches. Series PF2A for air, PF2W for water, PF2D for deionized water and chemicals. Flow rate setting and monitoring are possible with the digital display. Integrated and remote type displays are available for different types of application. Water resistant construction is used conforming to IP65 protection. Switching from real-time flow rate to accumulated

PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4 l/min 2 to 16 l/min 5 to 40 l/min 10 to 100 l/min Flow rate measuring range Operating pressure range Withstand pressure 0 to 1 MPa 1.5 MPa Operating fluid temperature 0 to 50C 0 to 50C Linearity Note 1) 5% F .S. or less 3% F .S. or less

Port size Nil N Lead wire with M12 connector (3 m) Without lead wire Port size Applicable model Flow rate (L/min) Symbol 100 4 16 40 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Output specifications Symbol Nil 1 2 Specification Series PF2W300 Series PF2W200/300 Series PF2W300 Applicable monitor unit (monitor) model Output for monitor unit Output

specification Nil N F Rc NPT G Nil N Lead wire with connector 3m Without lead wire Port size Applicable models Flow rate (l/min) Port size Symbol 40 100 4 16 03 04 06 10 3/8 1/2 3/4 1 PF2W504, PF2W520 PF2W520, PF2W540 PF2W540, PF2W511 PF2W511 Specifications PF2W504 PF2W520 PF2W540 PF2W511 Model Measured fluid Water Detection type Karman vortex 0.5 to 4l/min 2 to 16l/min 5 to 40l/min 10