Your search for NCQ2 returned 30 result(s)
There were no hits with the full part number, but there were 2 hits in the keyword search.
There were no hits with the full part number, but there were 1 hits in the keyword search.
Product Information » New Products Search Results
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Resistant: XB6 [Heat Resistant (-10 to 150°C)]
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC4 (w/Heavy Duty Scrapper
Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 63mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: Z (ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel)
Magnet: None, Mounting: Both Ends Tapped, Bore Size: 63mm, Stroke: 25mm, Body Option: Standard, Rod End Female Thread, Auto Switch Groove: ø12 to ø25, 2 Surfaces; ø32 to ø100, 4 Surfaces, Auto Switch: No Switch, Lead Wire: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Resistant: XB6 [Heat Resistant (-10 to 150°C)]
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1.0, Support bracket: Threaded, Port thread type: Rc, Body Options: Rod End Female Thread, Auto Switches
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,
SMC has redesigned the NCQ2 compact cylinder with a new body, making it possible to mount auto switches on any of the 4 surfaces, depending on the installation conditions. Auto switch mounting grooves have replaced the NCQ2's mounting rails, preventing projection of auto switches and improving ease and safety of work.Compact, double acting, single rod, large bore , Bore size (mm): 125,
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 63MM NCQ2-Z OTHERS (COMBO), ACTUATOR, NCQ2-Z COMPACT CYLINDER, PC, 63MM NCQ2-Z OTHERS (COMBO), 1.6874 lb
-100DZ (N)CDQ2B12-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ (N)CDQ2B16-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ (N)CDQ2B20-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2B25-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ (N)CDQ2B32-5DZ -10DZ -15DZ -20DZ -25DZ -30DZ -35DZ -40DZ -45DZ -50DZ -55DZ-XB10 -60DZ-XB10 -65DZ-XB10 -70DZ-XB10 -75DZ -80DZ-XB10 -85DZ-XB10 -90DZ-XB10 -95DZ-XB10
Mounting side Closed C B A A Open D Open E F F Mounting side MHL2-25DZ-X86/X86A MHL2-25D Z-X86/X86A 1 2 200 200 160 160 Gripping force [N] Gripping force [N] Pressure 0.6 MPa Pressure 0.6 MPa 0.5 MPa 120 120 0.5 MPa 0.4 MPa 0.4 MPa 80 80 0.3 MPa 0.3 MPa Closed F (Fingers closed) 40 40 0 0 40 80 120 160 200 0 0 40 80 120 160 200 [mm] Model A B C D E F Weight [g] MHL2-25DZ-X86(A) 9 106 128
(Example) CDQ2L32-25DZ *Specifications and dimensions for the 90-series are the same as standard products. 9091Applicable Auto Switch/Refer to pages 62 to 65 for further information on auto switches.