SMC Corporation of America
Elite Part Number Search
Search Results "NCMU044-0100"

Magnet: None, Mounting: U (Front Trunnion), Bore Size: 044 (7/16"), Stroke: 0100 (1"), Cushion: C (Rubber Bumper)

Magnet: None, Mounting: Front Trunnion, Bore Size: 7/16", Stroke: 1", Cushion: Rubber Bumper, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, NCM ROUND BODY CYLINDER, FD, 7/16 INCH NCM DOUBLE-ACTING, .00000 lb

Magnet: None, Mounting: U (Front Trunnion), Bore Size: 044 (7/16"), Stroke: 0200 (2"), Cushion: C (Rubber Bumper)

Magnet: None, Mounting: Front Trunnion, Bore Size: 7/16", Stroke: 0400, Cushion: -, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: None, Mounting: Front Trunnion, Bore Size: 7/16", Stroke: 2", Cushion: -, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: None, Mounting: Front Trunnion, Bore Size: 7/16", Stroke: 2", Cushion: Rubber Bumper, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: None, Mounting: Front Trunnion, Bore Size: 7/16", Stroke: 5", Cushion: -, Rod Boot: -, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: None, Mounting: Front Trunnion, Bore Size: 7/16", Stroke: 2", Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 1/8", Suffix: Required Selection w/Speed Control

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.