Bore size (mm) Auto switch model 12 to 25 32 40 to 100 D-A7l/A80 D-A73C/A80C D-A7lH/A80H D-A79W D-F7l/J79 D-F7lV D-J79C D-F7lW/J79W D-F7lWV D-F7BAL/F7BAVL D-F79F/F7NTL BQ-1 BQ-2 Auto Switch Mounting Bracket/Weight Mounting bracket part no.
(mm) Auto switch model Hw 23 Ht Hv D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C Auto switch model Hw 23 Hs Ht D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C Note 2) 2 magnets for auto switches are equipped to the magnet mounting block.
Same side Different sides Different sides Same side D-C7 D-A7/A80 D-A73C/A80C D-A7H D-A80H D-A79W 90 55 15 50 10 5 10 35 D-C80 D-C73C D-C80C D-H7C D-H7 D-H7W D-H7BAL D-H7NF 5 10 45 105 65 15 65 10 10 15 40 D-F7 D-J79 5 5 45 105 60 15 60 10 D-F7V 5 5 30 D-J79C D-F7W D-J79W 10 15 55 D-F7BAL D-F79F D-F7WV 10 15 40 D-F7BAVL D-A79W can not be mounted on bore size 8, 10, 12 cylinder.
Note D-F7/J79 D-F7V D-J79C D-F7W/J79W D-F7WV D-F7BAL/F7BAVL D-F79F D-F7NTL Switch mounting screw RS H A 20, 25 BQ-1 (M3 x 0.5 x 8l) Square nut D-A7/A8 D-A73C/A80C D-A7H/A80H D-A79W RZQ Switch mounting screw 32, 40 50, 63 Magnetic body (Steel plate, etc.)
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-F7BAL D-F79F D-F7WV 10 15 40 D-F7BAVL D-A79W can not be mounted on bore size 8, 10, 12 cylinder.
Spring extend) Single acting 6-3-64 Double acting Direct Mount, Non-Rotating Rod Series CJ2RK 6-3-68 Single rod Single acting Single rod, (Spring return/ Spring extend) 6-3-72 With end lock Series CBJ2 Double acting Single rod 16 6-3-77 Type Band mounting style Rail mounting style D-C7/C80, D-C73C/C80C D-A7/A80, D-A7H/A80H, D-A73C/A80C, D-A79W D-F7/J79, D-F7V, D-J79C, D-F7W/J79W, D-F7WV, D-F7BAL
D-A7/A8 D-A7H/A80H D-A73C/A80C 10 2 5 1 D-F7 D-J79 D-F7V D-J79C D-A79W D-F7W D-J79W D-F7BAL D-F7WV D-F79F Rail mounting 2 5 1 5 2 15 ( ) 10 1 10 16 2 15 D-F7LF 1 15 Note 1) Cannot be mounted on 6 cylinder. 1.3-14 Standard: Double Acting Double Rod Series CJ2W Mounting Accessories/Refer to p.1.3-12 details.
Same side Different sides Same side Different Same side sides D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/F7V D-J79/J79C 15 + 45 (n = 2, 4...) ( n 2) 2 D-C7 D-C80 10 15 50 50 + 45(n 2) ) 10 + 35 (n = 2, 4...) ( n2 2 10 5 D-C73C D-C80C D-H7C D-H7 D-H7W D-H7BAL D-H7NF 15 + 50 (n = 2, 4...) ( n 2) 2 10 15 65 65 + 50(n 2) D-A79W, D-J79W D-F7W, D-F7BAL D-F79F, F7WV D-F7BAVL ) 15 + 35 (n = 2, 4.
Same side Same side Different sides Different Same side sides D-A7/A80 D-A7H/A80H D-A73C/A80C D-F7/F7V D-J79/J79C 15 + 45 (n = 2, 4...) ( n 2) 2 D-C7 D-C80 10 50 50 + 45(n 2) 15 ) 10 + 35 (n = 2, 4...) ( n2 2 10 5 D-C73C D-C80C D-H7C D-H7 D-H7W D-H7BAL D-H7NF 15 + 50 (n = 2, 4...) ( n 2) 2 10 65 65 + 50(n 2) 15 D-A79W, D-J79W D-F7W, D-F7BAL D-F79F, F7WV D-F7BAVL ) 15 + 35 (n = 2, 4.
BBA2: For D-A7/A8/F7/J7 D-F7BAL auto switch is set on the cylinder with the stainless steel screws above when shipped. When only an auto switch is shipped independently, BBA2 screws are attached. Stainless Steel Mounting Screw Set Part no. Description Part Size Qty. Applicable auto switch mounting bracket part no. Applicable auto switch DNo.
BBA2: For D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped.
BBA2: For D-A7/A8/F7/J7 D-F7BAL/F7BAVL switch is set on the cylinder with the stainless steel screws above when shipped.
U A B D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7F D-F7NTL D-F7BAL SMC SMC Approx. U Approx. U Approx. U SMC SMC Approx. U A B B A Approx. U D-A73C D-A80C D-J79C B A A B Approx.
32, 40 RSDQ 20, 25, 32, 40, 50 MDU 25, 32, 40, 50, 63 CE1 12, 20, 32, 40, 50, 63 MK, MK2 20, 25, 32, 40, 50, 63 CXT 32, 40 Caution Specifications PLC: Programmable Logic Controller D-F7BAL (With indicator light) Precautions D-F7BAL Auto switch model number Consult SMC if using coolant liquid other than water based solution. 2 wire Wiring Output 24V DC Relay/PLC Application Power voltage
U 20 32 to 100 D-F7m D-J79 D-F7mW D-J79W D-F79F D-A7m D-A80 D-A7mH D-A80H D-F7NTL D-F7BAL D-J79C D-A79W D-F7mWV D-J7mV D-F7BAVL D-A73C D-A80C CHQ CHKm CHN Approx. U CHM B A Approx.
/Standard Stroke D-A72/A7H D-A80H/A73C D-A80C/F7/J79 D-F7W/J79W D-F7V/F7WV D-F79F/J79C D-F7BAL/F7BAVL Auto switch model D-A73 D-A80 D-A79W D-F7NTL Bore size A B 9.5 13.5 6.5 9 A B 6.5 10.5 3.5 6 A B 14.5 18.5 10.5 13 A B 32 40 9 13 6 8.5 (mm) Auto Switch Proper Mounting Position/Long Stroke D-A72/A7H D-A80H/A73C D-A80C/F7/J79 D-F7W/J79W D-F7V/F7WV D-F79F/J79C D-F7BAL/F7BAVL Auto switch model
Operating Range (mm) Auto switch model Bore size 12 16 20 25 32 40 50 63 D-M9/M9V D-M9W/M9WV D-M9AL/M9AVL D-A9/A9V 3.5 3.5 4 4 4 5 2 2.5 4.5 5 6.5 5.5 6.5 6.5 3 4 6 7.5 10 10 9.5 9.5 9.5 11.5 D-F7/J79 D-F7V/J79C D-F7W/F7WV D-J79W D-F79F/F7BAL D-F7BAVL/F7NTL 5.5 5 6 6 6 6.5 Since this is a guideline including hysteresis, not meant to be guaranteed.
BBA2: For D-A7/A8/F7/J7 types D-F7BAL/F7BAVL auto switches are mounted on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, BBA2 is attached.
BBA2: For D-A7/A8/F7/J7 types Water resistant auto switches, D-F7BAL/F7BAVL are set on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, BBA2 is attached.
Hs MLU MLGP A B ML1C Proper Auto Switch Mounting Position (mm) Auto Switch Mounting Height (mm) D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F7BAL D-F79F D-F7NTL Hs D-A72/A7H D-A80H/A73C D-A80C/F7 D-F7V/F79F D-J79/J79C D-F7W/F7WV D-J79W/F7BAL D-F7BAVL Auto switch type Auto switch type D-F7V D-F7WV D-F7BAVL D-A73 D-A80 D-A7 D-A80 D-A73C D-A80C D-A79W D-F7NTL D-J79C D-A79W Bore size Bore size A Hs