(Toronto) 6768 Financial Drive Mississauga, ON L5N 7J6 TEL: (905) 812-0400 FAX: (905) 812-8686 SMC Corporation of America (Charlotte) 5029-B West W.T. Harris Blvd.
D-A90, D-A93, D-A96 0.11 (2.7) 0.08(2) 0.11(2.8) OUT (-) Blue Blue 0.16(4) 0.87(22) [24.5] 4.5 M2.5 x 4l Slotted set screw Indicator light Type D-A90 without indicator light D-A96, A96V DC (+) Brown LED (+) Most sensitive position 0.39(10) The dimension inside [ ] is for D-A93.
Applicable load IC circuit, Relay, PLC Load voltage 24 V or less 48 V or less 100 V or less AC DC AC DC AC DC Maximum load current 50 mA 40 mA 20 mA Contact protection circuit None 1 or less (including lead wire length of 118"(3m)) Internal resistance D-A93, D-A93V, D-A96, D-A96V (With indicator light) D-A93, D-A93V D-A96, D-A96V Auto switch part no.
2761 Stroke (In Inches and Hundredths of Inches) NC1A 150 04 0400 Bore 150 200 250 325 400 Stroke (In Inches and Hundredths of Inches) Note: Quantity is one piece.
A96 Home position setting warning Home position setting could not be made. 1. Droop pulses remaining are greater than Remove the cause of droop pulse occurrence the in-position range setting. 2. Command pulse entered after clearing of Do not enter command pulse after clearing of droop pulses. droop pulses. 3. Creep speed high. Reduce creep speed.
A96 Home position setting warning Home position setting could not be made. 1. Droop pulses remaining are greater than Remove the cause of droop pulse occurrence the in-position range setting. 2. Command pulse entered after clearing of Do not enter command pulse after clearing of droop pulses. droop pulses. 3. Creep speed high. Reduce creep speed.
Franklin Road Indianapolis, IN 46226 (905) 812-0400 www.smcpneumatics.ca (800) 762-7621 (SMC.SMC1) www.smcusa.com For International inquires: www.smcworld.com 2008 SMC Corporation of America, All Rights Reserved. All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing.
Magnet: D (Built-in Magnet), Mounting: E (Double End Mount), Bore: 150 (1 1/2"), Stroke: 0400 (4"), Cushion: C (Bumper), Rod Boot: w/o Boot, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Environmental Options: XC6 (Stainless Steel Rod)
Magnet: D (Built-in), Mounting: C (Single Clevis), Cushion: N (Rubber Bumper), Bore Size: 20 (3/4"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: C (Single Clevis), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 32 (1 1/4"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 25 (1"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: B (Basic), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Type: K (Non-rotating), Mounting: U (Front Trunnion), Cushion: N (Rubber Bumper), Bore Size: 50 (2 Inch), Stroke: 0400 (4 Inch), Auto Switch: A96--Reed, DC Volt, LED, Horizontal
Magnet: D (Built-in), Mounting: E (Double End Mount), Bore Size: 075 (3/4"), Stroke: 0400 (4"), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Alarm deactivation Display Name (Note3) A90 Home positioning incomplete warning A92 Open battery cable warning MR (Note2) Display Name Power Configurator Alarm OFF ON 2TM reset A96 Home position setting error parameter (RES) A98 Software limit warning unit A10 Undervoltage A99 Stroke limit warning A12 Memory error 1 (RAM) A9D CC-Link warning 1 A13 Clock error A9E CC-Link warning 2 Warnings
Alarm deactivation Display Name (Note3) A90 Home positioning incomplete warning A92 Open battery cable warning MR (Note2) Display Name Power Configurator Alarm OFF ON 2TM reset A96 Home position setting error parameter (RES) A98 Software limit warning unit A10 Undervoltage A99 Stroke limit warning A12 Memory error 1 (RAM) A9D CC-Link warning 1 A13 Clock error A9E CC-Link warning 2 Warnings
Magnet: Built-in, Mounting: Double End, Bore Size: 2", Stroke: 0400, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -
Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/4", Stroke: 0400, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -