SMC Corporation of America
Elite Part Number Search
Search Results "NCDJPB15-100D-90A"

The length is 24 when any of the following are used: D-90/90A/S99(V)/T99(V)/S9P(V) The length is 30 when any of the following are used: D-97/93A The length is 25.5 when the D-M9 is used. *2.

New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2

SB, counterbore depth SC P .C.D.R (Mounting hole) Auto switch mounting groove positions (4 locations) MHS3-100D MHS3-125D 10 10 10 10 40 40 40 40 5 6.4 5 10 6.4 13 90 12 5 15 7 90 (mm) I G 63 84 FZ 10 12 FX 59 74 FY 54 68 CA 18 23.5 EC 28 30 EO 40 46 DC 66 82 DO 78 98 M 4 6 B 134 166 K 15 21 AC 6 8 J 38 52 AA 96 122 AB 90 114 NA 34 40 L +0.036 0 +0.036 0 NB Model MHS3-100D MHS3-125D CB 30.6

Part No M NA NB O P Q R SA SB SC TA TB UA MHS3-100D 4 34 18h9 -0.043~0 7.5 Rc(PT)1/4 23 118 9 14 21 M4x1.25 16 M8x1.25 MHS3-125D 6 40 22h9 -0.052~0 10.5 Rc(PT)3/8 31 148 11 17.5 34 M10x1.5 20 M10x1.5 Part No UB VA VB WA WB XA XB MHS3-100D 16 8H9 0~0.036 6 102H9 0~0.087 4 8H9 0~0.036 6 MHS3-125D 20 10H9 0~0.036 8 130H9 0~0.1 6 10H9 0~0.036 8 (mm) NOTE) FOR MHS2 AND MHS4 DIMENSIONS AND MORE

The length is 24 when any of the following auto switches are used: D-90/90A/S99(V)/T99(V)/S9P(V) The length is 30 when any of the following auto switches are used: D-97/93A 2.

P Q R SA SB SC TA TB UA MHS3-100D 4 34 18h9 -0.043~0 7.5 Rc(PT)1/4 23 118 9 14 21 M4x1.25 16 M8x1.25 MHS3-125D 6 40 22h9 -0.052~0 10.5 Rc(PT)3/8 31 148 11 17.5 34 M10x1.5 20 M10x1.5 Part No UB VA VB WA WB XA XB MHS3-100D 16 8H9 0~0.036 6 102H9 0~0.087 4 8H9 0~0.036 6 MHS3-125D 20 10H9 0~0.036 8 130H9 0~0.1 6 10H9 0~0.036 8 (mm) Courtesy of Steven Engineering, Inc. !

Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 15 (5/8 Inch), Stroke: 037 (3/8 Inch), Rod End Thread: Thread, Auto Switch: 90A--Reed, DC Volt, AC Volt, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 15 (5/8 Inch), Stroke: 075 (3/4 Inch), Rod End Thread: Thread, Auto Switch: 90A--Reed, DC Volt, AC Volt, Horizontal, 0.5M

Magnet: D (Built-in), Mounting: B (Basic Style), Bore Size: 15 (5/8 Inch), Stroke: 125 (1 1/4 Inch), Rod End Thread: Thread, Auto Switch: 90A--Reed, DC Volt, AC Volt, Horizontal, 0.5M

Magnet: Built-in, Mounting: Basic Style, Bore Size: 5/8 Inch, Stroke: 3/8 Inch, Rod End Thread: Thread, Auto Switch: 90A--Reed, DC Volt, AC Volt, Horizontal, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 5/8 Inch, Stroke: 3/4 Inch, Rod End Thread: Thread, Auto Switch: 90A--Reed, DC Volt, AC Volt, Horizontal, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 5/8 Inch, Stroke: 1 1/4 Inch, Rod End Thread: Thread, Auto Switch: 90A--Reed, DC Volt, AC Volt, Horizontal, 0.5M, Number: -

Magnet: Built-in, Mounting: Basic Style, Bore Size: 5/8 Inch, Stroke: 1 Inch, Rod End Thread: -, Auto Switch: -, Number: -

CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M3 x 25l x 30l x 35l x 40l x 45l x 50l M3 x 25l x 30l x 35l x 40l x 45l x 50l

CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B63-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D M8 x 50l x 55l x 60l x 65l x 70l x 75l x 80l x 85l x 90l x 125l x 150l M10

CQ2B80-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B100-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B32-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B40-5D -10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D CQ2B50-10D -15D -20D -25D -30D -35D -40D -45D -50D -75D -100D 6.5 14.5 9 5 15 7.5 7.5 9.5 15.5 12.5 2.3-5 Series CQ2 Construction Component

The lead wire length to the load is 5m or more. 92 Reed Switches: Direct Mount Type D-90A, D-93A Specifications Grommet Lead wire: Heavy-duty cord D-90A (without indicator light) Applicable load D-90A Auto switch part no.

4 6 P NC 21 25 TB 16 20 UA M8 x 1.25 UB 16 20 8H9 10H9 VA Model MHSL3-100D MHSL3-125D Rc 1/4 (G 1/4, NPT 1/4) Rc 3/8 (G 3/8, NPT 3/8) +0.036 0 +0.036 0 0 -0.043 0 -0.052 +0.036 0 +0.036 0 8H9 18h9 10H9 22h9 M10 x 1.5 M10 x 1.5 XA XB 6 8 VB 6 8 WA WB 4 6 Model MHSL3-100D MHSL3-125D +0.036 0 +0.036 0 +0.087 0 +0.100 0 8H9 102H9 10H9 130H9 594 Series MHSL3 Parallel Style Air Gripper/3-Finger

The length is 24 when any of the following auto switches are used: D-90, D-90A, D-S99(V), D-T99 and D-S9P(V). The length is 30 when any of the following auto switches are used: D-97 and D-93A. 2. The angle is 60 when any of the following auto switches are used: D-90, D-90A, D-97 and D-93A.