Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: Built-in, Mounting: Double Clevis, Bore: Ø10 (3/8 inch), Stroke: 1 Inch, Action: Spring Return, Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 1 pc.
Series NCJ2 miniature cylinders available in spring return, spring extend, or double acting all offer stainless steel tubing and stainless steel rods. Available in bore sizes 6, 10, 16mm and stroke lengths from 1/2in. to 8in.. Basic, foot, front flange and double rear clevis mounting options. Auto-switch capable. Other features include non-rotating, double rod, rubber bumpers and a stainless
Low speed cylinder Bore size 20 25 32 40 20mm 25mm 32mm 40mm Type of auto switch Reed switch Solid state switch C73 H7B, H7A1 Cylinder stroke (mm) Refer to the standard stroke table below.
Output) Pre-wire connector Applicable load Special function Applicable bore size (mm) 0.5 (Nil) 3 (L) 5 (Z) None (N) AC DC 80, 100 20 to 63 3-wire (NPN equivalent) IC circuit 5 V C76 Reed switch Solid state switch Grommet B54 C73 C73C 100 V, 200 V 100 V Yes Yes 12 V Relay, PLC 2-wire 24 V Connector Diagnostic indication (2-color indication) Grommet B59W G59 G5P K59 G59W G5PW K59W H7A1
C76E32-100S 1 pc. Cylinder 2. Cylinder with auto switch (Band mounted type, 2 pcs.), Bore size: 40, Stroke: 100, Single acting/Spring return, Front nose in line port type and Flange mounting. CD76Y40-100S-B 1 pc. Cylinder C76F40A 1 pc. Flange mounting D-C73L 2 pcs. Auto switch BM2-040 2 pcs. For auto switch mounting band 3.
C76E32-100S 1 pc. Cylinder 2. Cylinder with auto switch (Band mounted type, 2 pcs.), Bore size: 40, Stroke: 100, Single acting/Spring return, Front nose in line port type and Flange mounting. CD76Y40-100S-B 1 pc. Cylinder C76F40A 1 pc. Flange mounting D-C73L 2 pcs. Auto switch BM2-040 2 pcs. For auto switch mounting band 3.
Electrical entry Applicable bore size 0.5 () 3 (L) 5 (Z) None (N) DC AC 20 to 63 20 to 100 3 wire (NPN) C76 IC 5V Yes B53 PLC B54 12V Grommet 200V or less Reed switch Solid state switch B64 No 100V 12V C73 Yes 2 wire 24V Relay PLC 100V or less 5V, 12V C80 No IC 12V C73C Yes Connector 24V or less 5V, 12V C80C No IC B59W Yes Grommet Diagnostic indication (2 color) 3 wire (NPN) H7A1
Auto switch model Pre-wire connector Applicable load 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC 3-wire (NPN equivalent) C76 IC circuit 5 V Grommet C73 B54 C73C A33A A34A A44A 100 V Relay, PLC 100 V, 200 V Reed switch Solid state switch Connector 12 V Yes Yes PLC Terminal conduit 2-wire 24 V 100 V, 200 V DIN terminal Relay, PLC Diagnostic indication (2-color indication) B59W Grommet H7A1
Auto switch Lead wire* (m) Without auto switch (Built-in magnet) Load voltage Indicator Style Special function Wiring (Output) Electrical entry Auto switch model Applicable load 0.5 () 3 (L) 5 (Z) None (N) DC AC * Refer to the left table for selecting applicable auto switches. 3 wire (NPN) C76 C73 C80 B53 B54 B64 C73C C80C A33A A34A A44A B59W H7A1 H7A2 H7B H7C G39A K39A H7NW H7PW H7BW H7BA
Applicable crimp-style terminal 1.25Y-3L, 1.25-3.5S, 1.25-4M 90
Technical Data 2: How to Mount and Move the Auto Switch Mounting Bracket Band Mounting Style Caution
125S 150S 175S 200S NCDQ8B075-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B106-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B150-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B200-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B250-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S #10-24UNC2-1/8 2-1/4 2-3/8 2-1/2 2-5/8 2-3/4
125S 150S 175S 200S NCDQ8B075-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B106-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B150-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B200-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S NCDQ8B250-025S 037S 050S 062S 075S 087S 100S 125S 150S 175S 200S #10-24UNC-2 1/8 2 1/4 2 3/8 2 1/2 2 5/8 2 3/4
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: B (Band Mounting)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C80C--Reed, DC Volt >5 <24, AC Volt <100, Connector
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal
Magnet: D (Built-in), Mounting: D (Double Clevis), Bore: Ø10 (3/8 inch), Stroke: 100 (1 Inch), Action: S (Spring Return), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP