(Example) CDM2F40-100T Auto switch 40 mm Without auto switch Nil For the applicable auto switch model, refer to the table below. Applicable Auto Switch/Refer to pages 1263 to 1371 for further information on auto switches.
Auto Switch Specifications Connector PLC: Abbreviation of Programmable Logic Controller D-C73C (With indicator light) D-C73C Auto switch model Applicable load Relay, PLC Load voltage 24 VDC (4) Load current range 5 to 40 mA Contact protection circuit None Internal voltage drop 2.4 V or less Indicator light Red LED lights when ON.
D-H7C D-B5, D-B6, D-B59W Auto switch Auto switch Hs Hs Single Acting, Spring Return Single Acting, Spring Extend Bore size (mm) A B All stroke A Bore size (mm) B Auto switch model Auto switch model 150 200 Hs Hs All stroke 150 200 125 125 50 100 50 100 25 75 25 75 20 20 30 105 95.5 55 80 45.5 70.5 55 80 45.5 70.5 24.5(27) 24.5(27) 20.5 D-C7 D-C8 D-C73C D-C80C D-C7 D-C8 D-C73C D-C80C 25 25
D-C80C D-H7C Auto Switch Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C D-H7 D-H7C D-H7W D-H7BAL D-H7NF Bore A B A B 32 8 7 7 6 40 14 12 13 11 Aim at this number.
D-C80C D-H7C Auto Switch Mounting Position (mm) D-C7 D-C80 D-C73C D-C80C D-H7 D-H7C D-H7W D-H7BAL D-H7NF Bore B A B A 32 6 7 7 8 40 11 13 12 14 Aim at this number.
125T 150T 175T 200T NCDQ8B075-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B106-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B150-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B200-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B250-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T #10-24UNC2-5/8 2-3/4 2-7/8 3 3-1/8 3-1/4 3-3/
125T 150T 175T 200T NCDQ8B075-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B106-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B150-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B200-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T NCDQ8B250-025T 037T 050T 062T 075T 087T 100T 125T 150T 175T 200T #10-24UNC-2 5/8 2 3/4 2 7/8 3 3 1/8 3 1/4 3 3
Replacement parts Material Description NBR Y100T Y100P-060AS Note) Y200T Y200P-060S Y300T Y300P-060S Y400T Y400P-060S Y500T Y500P-060S Y600T Y600P-060S Seal Note) Y-100T comes with 2 O-rings. 18 Series AC Mounting Position for Spacer with Bracket Bracket T-interface: T 3-port valve for residual pressure: V Check valve: K Pressure switch: S SUP A A A IN IN OUT OUT A Bracket L3 L2 L1 L1 L4
Y100T Y200T Y300T Y400T Y500T Y600T Seal HNBR Note 2) Y100P-060AS Note 1) Y200P-060S Y300P-060S Y400P-060S Y500P-060S Y600P-060S Note 1) Y-100T comes with 2 O-rings.
Replacement Parts Material Description HNBR (2) Y100T Y100P-060AS (1) Y200T Y200P-060S Y300T Y300P-060S Y400T Y400P-060S Y500T Y500P-060S Y600T Y600P-060S Seal Note 1) Y-100T comes with 2 O-rings.
Replacement Parts Material Description HNBR (2) Y100T Y100P-060AS (1) Y200T Y200P-060S Y300T Y300P-060S Y400T Y400P-060S Y500T Y500P-060S Y600T Y600P-060S Seal Note 1) Y-100T comes with 2 O-rings.
Replacement parts Material Description HNBR Note 2) Y100T Y100P-060AS Note 1) Y200T Y200P-060S Y300T Y300P-060S Y400T Y400P-060S Y500T Y500P-060S Y600T Y600P-060S Seal Note 1) Y-100T comes with 2 O-rings.
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: B (Basic), Bore: Ø16 (5/8 Inch), Stroke: 100 (1 Inch), Action: T (Spring Extend), Port Location: Perpendicular, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)