SMC Corporation of America
Elite Part Number Search
Search Results "NCDGNN32-0100-M9PSAPC"

This is a legacy product, and replaced byMGPL20TN-200AZ-M9PSAPC-XC9 MGP COMPACT GUIDE CYLINDER. CYL, GUIDE, B/BRG,ADJ STK/RETR. ACTUATOR. 20MM MGP. .00000 lb. HC.

This is a legacy product, and replaced byMGPM20-20Z-M9PSAPC, CYL, COMPACT GUIDE, SLIDE *LQA, ACTUATOR, MGP COMPACT GUIDE CYLINDER, HM, 20MM MGP SLIDE BEARING, 3.94390 lb, Bore size (mm)ModelStandard stroke (mm) 1020253040507510012515017520025030035040020MGPM20?0.67?0.750.830.911.171.371.571.761.962.162.633.033.423.82

This is a legacy product, and replaced byCDG1BN20-50Z-M9PSAPC, CYL, AIR, DBL ACT, AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, HE, 20MM CG DBL-ACT AUTO-SW, .88184 lb

This is a legacy product, and replaced byCY1SG10-130BZ-M9PSAPC, CYL, RODLESS, SLIDER, SW CAP, ACTUATOR, CY1S GUIDED CYLINDER, EM, 10MM CY1S SLIDE BEARING, 2.30107 lb

This is a legacy product, and replaced byCDM2B25-200Z-M9PSAPC, CYL, RND BODY, DBL ACTING, ACTUATOR, CM2/CM3 ROUND BODY CYLINDER, IE, 25MM CM2 DBL-ACT AUTO-SW, 1.31143 lb

This is a legacy product, and replaced byCDG1BN20-125Z-M9PSAPC, 20MM CG DBL-ACT AUTO-SW, ACTUATOR, CG/CG3 ROUND BODY CYLINDER, HE, 20MM CG DBL-ACT AUTO-SW, 0.88309 lb

This is a legacy product, and replaced byCDG1BN25-350Z-M9PSAPC, 25MM CG DBL-ACT AUTO-SW, ACTUATOR, 25MM CG DBL-ACT AUTO-SW, 1.76369 lb

Magnet: D (Built-in), Mounting: N (Front Nose Mount), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke: 0100 (1")

Magnet: Built-in, Mounting: Front Nose Mount, Cushion: Rubber Bumper, Bore Size: 1 1/4", Stroke: 1", Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Magnet: Built-in, Mounting: Front Nose Mount, Cushion: Rubber Bumper, Bore Size: 1 1/4", Stroke: 1", Auto Switch: G59--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Front Nose Mount, Cushion: Rubber Bumper, Bore Size: 1 1/4", Stroke: 1", Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Front Nose Mount, Cushion: Rubber Bumper, Bore Size: 1 1/4", Stroke: 1", Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Range Setting Enabled Section 2 Output Signal Selection 1 0 to 3 0 After restart Setup Pn50E 2 Output Signal Selection 2 0 to 3 0100 After restart Setup Pn50F 10-19 10 List of Parameters (contd) Parameter Name Setting Units Factory When Classification Profile Reference Size No.

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

2"), 0100 (1"), 0150 (1-1/2"), 0200 (2"), 0250 (2-1/2"), 0300 (3"), 0400 (4"), 0600 (6") Double acting Double rod 075 (3/4") 088 (7/8") 106 (1-1/16") 125 (1-1/4") 150 (1-1/2") 0050 (1/2"), 0100 (1"), 0200 (2"), 0300 (3"), 0400 (4"), 0500 (5") 0600 (6") Single acting Single rod Now available in 8 different bore sizes, 7/16" to 2".