Product Information » New Products Search Results
Magnet: D (Built-in), Mounting: L (Foot), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke: 1800 (18"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: Built-in, Mounting: Foot, Cushion: Rubber Bumper, Bore Size: 1 1/2", Stroke: 18", Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -
The NCG provides precision mounting, short overall length, and high speed. Rubber bumpers are standard and an optional adjustable air cushion is available. Nine mounting styles include basic body, foot, single clevis, front or rear flange, front or r, NCG Cylinder, ROUND BODY CYLINDER, E20, 2.266 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, AIR 1 1/2 BORE, ACTUATOR, NCG ROUND BODY CYLINDER, ME, 40MM NCG DBL-ACT AUTO-SW
The spacing (l) of the support must be no more than the values shown in the graph on the right. 200 (kg) m 190 (2100) (2100) (2100) (2100) 180 170 l 160 150 140 130 (1800) (1800) (1800) (1800) Caution m l 120 Weight (m) 110 MY1M63 MY1M63 MY1M63 MY1M63 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation.
1200 600 1800 1200 600 501 to 600 1580 1050 520 1800 1200 600 601 to 700 1170 780 390 1800 1200 600 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110 740 370 901 to 1000 580 390 190 900 600 300 1001 to 1100 480 320 160 750 500 250 1101 to 1200 410 270 130 630 420 210 1201 to 1300 540 360 180 1301 to 1400 470 310 150 1401 to 1500 410 270 130 Max. acceleration/deceleration [mm
) (4500 rpm) (3938 rpm) (2925 rpm) (2250 rpm) (1800 rpm) (1463 rpm) (1200 rpm) (1013 rpm) H 30 1800 1390 1110 900 750 630 540 470 410 A 20 1200 930 740 600 500 420 360 310 270 LEJS63 200 W equivalent B 10 600 460 370 300 250 210 180 150 130 (Motor rotation speed) (3600 rpm) (2790 rpm) (2220 rpm) (1800 rpm) (1500 rpm) (1260 rpm) (1080 rpm) (930 rpm) (810 rpm) 825 LEJS Series Motorless
1200 600 1800 1200 600 501 to 600 1580 1050 520 1800 1200 600 601 to 700 1170 780 390 1800 1200 600 701 to 800 910 600 300 1390 930 460 801 to 900 720 480 240 1110 740 370 901 to 1000 580 390 190 900 600 300 1001 to 1100 480 320 160 750 500 250 1101 to 1200 410 270 130 630 420 210 1201 to 1300 540 360 180 1301 to 1400 470 310 150 1401 to 1500 410 270 130 Max. acceleration/deceleration [mm
CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v
40 28 65 1401 to 1800 50 33 75 1401 to 1800 63 43 90 1501 to 1800 80 100 Applicable to the CH2E, CH2F and CH2H series.
BMY3-016 Auto switch model Tightening torque D-M9l(V) D-M9lW(V) 0.10 to 0.15 210 Solid State Auto Switch Direct Mounting Type D-M9N(V)/D-M9P(V)/D-M9B(V) RoHS Refer to SMC website for the details of the products conforming to the international standards.
The spacing (l) of the support must be no more than the values shown in the graph on the right. 200 (kg) m 190 (2100) (2100) (2100) (2100) 180 170 l 160 150 140 130 (1800) (1800) (1800) (1800) Caution m l 120 Weight (m) 110 MY1M63 MY1M63 MY1M63 MY1M63 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation.
) (3938 rpm) (2925 rpm) (2250 rpm) (1800 rpm) (1463 rpm) (1200 rpm) (1013 rpm) H 30 1800 1390 1110 900 750 630 540 470 410 A 20 1200 930 740 600 500 420 360 310 270 LEJS63 200 W/ m60 B 10 600 460 370 300 250 210 180 150 130 (Motor rotation speed) (3600 rpm) (2790 rpm) (2220 rpm) (1800 rpm) (1500 rpm) (1260 rpm) (1080 rpm) (930 rpm) (810 rpm) 121 LEJ Series AC Servo Motor Clean Room Specication
) (3938 rpm) (2925 rpm) (2250 rpm) (1800 rpm) (1463 rpm) (1200 rpm) (1013 rpm) H 30 1800 1390 1110 900 750 630 540 470 410 A 20 1200 930 740 600 500 420 360 310 270 LEJS63 200 W/ m60 B 10 600 460 370 300 250 210 180 150 130 (Motor rotation speed) (3600 rpm) (2790 rpm) (2220 rpm) (1800 rpm) (1500 rpm) (1260 rpm) (1080 rpm) (930 rpm) (810 rpm) 121 LEJ Series AC Servo Motor Clean Room Specication
Lead wire length (m) Load voltage Indicator light Special function Wiring (Output) Electrical entry Type Applicable load Auto switch model 0.5 (Nil) 3 (L) 5 (Z) DC AC A90 IC circuit No 100 V or less 5 V, 12 V Reed switch Relay, PLC 2-wire 24 V Grommet A93 Yes 100 V 12 V M9N 3-wire (NPN) IC circuit Solid state switch 5 V, 12 V Relay, PLC M9P Grommet 3-wire (PNP) 24 V Yes M9B 2-wire
MY1CW MY1MW m 200 200 190 (kg) (kg) 190 (2100) (2100) (2100) (2100) 180 180 l 170 170 160 160 150 150 140 140 m l (2400) (2400) (2400) (2400) (2400) (2400) 130 130 (1800) (1800) (1800) (1800) m 120 120 Weight (m) Weight (m) 110 110 MY1MW63 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) (2000) l l 90 90 (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 80 80 MY1MW50 MY1MW50 MY1MW50 Caution
Load voltage Auto switch model Lead wire length [m] Pre-wired connector Applicable load DC AC Tie-rod mounting Band mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) Indicator light Wiring (Output) Type Special function Electrical entry 3-wire (NPN) 24 V 5 V, 12 V M9N V V V v v IC circuit 3-wire (PNP) M9P V V V v v 2-wire 12 V M9B V V V v v Terminal conduit 3-wire (NPN) Grommet G39 2-wire 12 V
MY1CW MY1MW m 200 200 190 (kg) (kg) 190 (2100) (2100) (2100) (2100) 180 180 l 170 170 160 160 150 150 140 140 m l (2400) (2400) (2400) (2400) (2400) (2400) 130 130 (1800) (1800) (1800) (1800) m 120 120 Weight (m) Weight (m) 110 110 MY1MW63 MY1MW63 MY1MW63 100 100 (2000) (2000) (2000) (2000) (2000) (2000) l l 90 90 (1500) (1500) (1500) (1500) MY1CW63 MY1CW63 80 80 MY1MW50 MY1MW50 MY1MW50 Caution
W (N) 600 (1800) l 500 ML2B40 ML2B40 Caution (1500) If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting.