SMC Corporation of America
Elite Part Number Search
Search Results "NCDGBN40-0800+0100-XC10"

Magnet: None, Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 50 (2"), Stroke A: 0800 (8"), +: None, Stroke B: 0800 (8"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: D (Built-in), Mounting: R (Side Tapped), Bore Size: 200 (2"), Stroke A: 0800 (8"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0800 (8"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: Built-in, Mounting: Basic, Bore Size: 1 1/2", Stroke A: 8", Stroke B: 1", Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: Dual Stroke, Double Rod

Magnet: None, Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 0400 (4"), +: None, Stroke B: 0800 (8"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 150 (1 1/2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0800 (8"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 400 (4"), Stroke A: 0800 (8"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1000 (10"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0800 (8"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1600 (16"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: N (No Lead Wire), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0800 (8"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1600 (16"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 0100 (1"), +: None, Stroke B: 0200 (2"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: None, Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 32 (1 1/4"), Stroke A: 0100 (1"), +: None, Stroke B: 0200 (2"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 40 (1 1/2"), Stroke A: 0100 (1"), +: None, Stroke B: 0600 (6"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: D (Built-in), Mounting: B (Basic), Cushion: N (Rubber Bumper), Bore Size: 50 (2"), Stroke A: 0100 (1"), +: None, Stroke B: 0250 (2 1/2"), Stroke Adjustment: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC10 (Dual Stroke, Double Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 250 (2 1/2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0200 (2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 200 (2"), Stroke A: 0100 (1"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1000 (10"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: None, Mounting: B (Basic), Bore Size: 200 (2"), Stroke A: 0400 (4"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 325 (3 1/4"), Stroke A: 0050 (1/2"), Cushion A: Both Ends, Rod Boot A: None, Stroke B: 0100 (1"), Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: XC10 (Dual Op., Dbl. Rod)

0h general error 0800 0020h Data cannot be transferred or stored to the application. 0800 0021h Data cannot be transferred of stored to the application because of local control. 0800 0022h Data cannot be transferred or stored to the application because of the present device state.