SMC Corporation of America
Elite Part Number Search
Search Results "MY1HT50G-1000H-Y59BL"

Mechanically Jointed Rodless Cylinder/Linear Guide Type Construction Series MY1H 10 Replacement Procedure is P.310 Centralized piping type: 10 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !8 !6 !7 !4 !9 !3 The numbers are the same as the "Construction

For the corresponding parameters, refer to "Parameter". 18.7.3.1 General Objects (1) Device Type (1000h) Index Sub Name Data Type Access PDO Mapping 1000h 0 Device Type UNSIGNED32 ro Impossible Index Sub Default Range Units EEP-ROM Parameter 1000h 0 00020192h 00020192h to 00020192h Impossible The value "00020192h", which indicates a servo drive defined with the CiA 402 profile, is returned

Bore Size: 50mm, Port Thread: Rc, Piping: Centralized Piping, Stroke: 1000mm, Stroke Adjusting Unit: 2 Shock Absorbers at Each Stk End, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 50mm, Port Thread: Rc, Piping: G (Centralized Piping), Stroke: 1000mm, Stroke Adjusting Unit: H (2 Shock Absorbers at Each Stk End)

Byte 0 1 2 3 4 5 6 7 Error register Object Emergency Error Code Manufacturer specific Error Field Structure of the Emergency Object Data Error code (Hex) Meaning 0h Error Reset (or No Error) 1000h Generic Error 8110h CAN Over-run 8120h CAN in Error Passive Mode 8130h Life Guard Error or Heartbeat Error 8210h PDO not processed due to length error Emergency Error Code Error register Object

Symbol Name Initial value Unit Standard P S T PA01 *STY Operation mode 1000h PA02 *REG Regenerative option 0h PA03 *ABS Absolute position detection system 0h PA04 *AOP1 Function selection A-1 2000h PA05 *FBP Number of command input pulses per revolution 10 PA06 CMX Electronic gear numerator (command pulse multiplication numerator) 1 PA07 CDV Electronic gear denominator (command pulse multiplication

Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ Refer to page 8-12-24 for details on other applicable auto switches than listed above.

Bore Size: 50mm, Port Thread: Rc, Piping: Centralized Piping, Stroke: 1000mm, Stroke Adjusting Unit: 2 Shock Absorbers at Each Stk End, Auto Switch: Y69A--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: -, Number: -

Bore Size: 50mm, Port Thread: Rc, Piping: G (Centralized Piping), Stroke: 1000mm, Stroke Adjusting Unit: H (2 Shock Absorbers at Each Stk End), Auto Switch: Y69A--Solid State, Gen. Purpose, 3 Wire NPN, Vertical

Connector type D-Y59AL 3 Wire Solid State NPN 28VDC or less Max 150mA 5~28VDC 0.8V Max ON:RED LED D-Y7PL 3 Wire Solid State PNP 28VDC or less Max 100mA 5~28VDC 0.8V Max ON:RED LED D-Y59BL 2 Wire Solid State 28VDC or less 5~ 150mA 3V Max ON:RED LED Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 !

Connector type D-Y59AL 3 Wire Solid State NPN 28VDC or less Max 150mA 5~28VDC 0.8V Max ON:RED LED D-Y7PL 3 Wire Solid State PNP 28VDC or less Max 100mA 5~28VDC 0.8V Max ON:RED LED D-Y59BL 2 Wire Solid State 28VDC or less 5~ 150mA 3V Max ON:RED LED Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 !

DC AC 5 V, 12 V Y69A Y7PV Y69B Y59A Y7P Y59B IC circuit 3-wire (NPN) 3-wire (PNP) Solid state switch 5 V, 12 V 3-wire (NPN) 12 V 2-wire Standard Relay, PLC Y7NWV Y7NW Y7PWV Y7PW Y7BW Diagnosis (2-color indication) IC circuit 24 V Grommet Yes 3-wire (PNP) Y7BWV 2-wire 12 V Water resistant (2-color indication) Y7BA Lead wire length symbols: 0.5 m Nil (Example) Y59B 3 m L (Example) Y59BL

Lead wire length symbols: 0.5 mNil (Example) A93 3 mL (Example) Y59BL 5 mZ (Example) F9NWZ There are other applicable auto switches than listed above. For details, refer to page 8-11-101.

D-Y59BL 2 pcs. 25 15 D-Y69BL 1 pcs. D-Y7PL Solid state switch CJ1 Auto switches are mounted on the same side but in different grooves of the cylinder.

D-Y59BL 2 pcs. 25 15 D-Y69BL 1 pcs. D-Y7PL Solid state switch CJ1 Auto switches are mounted on the same side but in different grooves of the cylinder.

Symbol Name Initial value Refference [Pr.PA01] **STY Operation mode 1000h Section 4.1 [Pr.PA02] **REG Regenerative option 0h Section 4.2 [Pr.PA03] *ABS Absolute position detection system 0h Section 4.3 [Pr.PA04] *AOP1 Function selection A-1 2000h Section 4.4 [Pr.PA06] *CMX Electric gear numerator/Number of gear teeth on machine side 1 Refer to the recommended parameter values for each actuator

Symbol Name Initial value Unit Setting PA01 **STY Operation mode 1000h PA02 **REG Regenerative option 0h PA03 *ABS Absolute position detection system 0h PA04 *AOP1 Function selection A-1 2000h PA05 For manufacturer setting 10 PA06 1 PA07 1 PA08 ATU Auto tuning mode 0001h PA09 RSP Auto tuning response 16 PA10 INP In-position range 1600 [pulse] PA11 For manufacturer setting 1000.0 PA12 1000.0

PA_ _ ]) PA01 **STY 1000h PA02 **REG 0h PA03 *ABS 0h PA04 *AOP1 A-1 2000h PA05 10 PA06 1 PA07 1 PA08 ATU 0001h PA09 RSP 16 PA10 INP 1600 [pulse] PA11 1000.0 PA12 1000.0 PA13 0h PA14 *POL 0 PA15 *ENR 4000 [pulse/rev ] PA16 *ENR2 2 1 PA17 **MSR 0h PA18 **MTY 0h PA19 *BLK 00ABh PA20 *TDS Tough Drive 0h PA21 *AOP3 A-3 0001h PA22 **PCS 0h PA23 DRAT 0h PA24 AOP4 A-4 0h PA25 OTHOV

Symbol Name Initial value Unit PA01 STY Operation mode 1000h PA03 ABS Absolute position detection system (Note 1) 0h PA04 AOP1 Function selection A-1 2000h PA08 ATU Auto tuning mode (Note 1) 0001h PA09 RSP Auto tuning response (Note 1) 16 PA10 INP In-position range (Note 1) 1600 pulse PA14 POL Rotation direction selection (Note 1) 0 (2) Extension setting parameters (No.PC ) No.