Contents Bore size (mm) MXF8-PS 8 12 16 20 MXF8-PS MXF12-PS MXF16-PS MXF20-PS !7 !8 !9 Piston seal MXF12-PS MXF16-PS MXF20-PS Set of left nos. !7, !8, !9 Rod seal NBR O-ring Seal kit includes !7, !8, !9. Order the seal kit, based on each bore size. Replacement Parts: Grease Pack Grease pack part no.
, 100 25 10, 20, 30, 40, 50, 75, 100 32 10, 20, 30, 40, 50, 75, 100 10 75, 100, 125, 150 15 75, 100, 125, 150 20 125, 150, 175, 200 25 125, 150, 175, 200 32 125, 150, 175, 200 Courtesy of Steven Engineering, Inc. !
, 100 25 10, 20, 30, 40, 50, 75, 100 32 10, 20, 30, 40, 50, 75, 100 10 75, 100, 125, 150 15 75, 100, 125, 150 20 125, 150, 175, 200 25 125, 150, 175, 200 32 125, 150, 175, 200 Courtesy of Steven Engineering, Inc. !
F A A MX Lr MTS MXF16 Lr = 40 mm MY 0.20 0.07 0.07 CY 0.06 0.06 MXF16-75 Table displacement amount (mm) Table displacement amount (mm) Table displacement amount (mm) 0.16 MXF16-75 MXF16-75 MXF16-50 MXF16-30 0.05 0.05 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
MXF12 0.47 M2.5 x 8 MXF16 0.88 M3 x 10 MXF20 M4 x 14 2.06 Loctite No. 242 of Henkel Japan Ltd. or its equivalent is applied. 1-7.
Max. tightening torque ft lbf (N m) Max. screw-in depth L (mm) Max. tightening torque ft lbf (N m) Max. screw-in depth L (mm) Model Model Bolt used Bolt used 6 6.5 0.7 {0.9} 0.7 {0.9} M3 x 0.5 M3 x 0.5 MXF8 MXF8 6 5.5 0.7 {0.9} 0.7 {0.9} M3 x 0.5 M3 x 0.5 MXF12 MXF12 10 6.5 1.5 {2.1} 1.5 {2.1} M4 x 0.7 M4 x 0.7 MXF16 MXF16 12 9.5 3.2 {4.4} 1.5 {4.4} M5 x 0.8 M5 x 0.8 MXF20 MXF20 18 Long
Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV
Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV
Contents Bore size (mm) MXF8-PS 8 12 16 20 MXF8-PS MXF12-PS MXF16-PS MXF20-PS !7 !8 !9 Piston seal MXF12-PS MXF16-PS MXF20-PS Set of left nos. !7, !8, !9 Rod seal NBR O-ring Seal kit includes !7, !8, !9. Order the seal kit, based on each bore size. Replacement Parts: Grease Pack Grease pack part no.
Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L
, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L
Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L
, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L
The actuator is equipped with location holes for quick and easy mounting changes of tools or fixtures., STROKE ADJ (MXF16), ACTUATOR, MXF GUIDED CYLINDER, G2, 16MM MXF KIT/ACCESSORY, .00880 lb
The actuator is equipped with location holes for quick and easy mounting changes of tools or fixtures., STROKE ADJ (MXF16), ACTUATOR, MXF GUIDED CYLINDER, G2, 16MM MXF KIT/ACCESSORY, .01672 lb
The actuator is equipped with location holes for quick and easy mounting changes of tools or fixtures., STROKE ADJ (MXF16), ACTUATOR, MXF GUIDED CYLINDER, G2, 16MM MXF KIT/ACCESSORY, .01100 lb