(The switch will stay ON all the time.) 1) For an auto switch without a contact protection circuit, use a contact protection box when the wire length is 5m or longer. 2) Even if an auto switch has a built-in contact protection circuit, when the wiring is more than 30m long, it is not able to adequately absorb the rush current and its life may be reduced.
Precision Cylinder Series MTS Precision Cylinder Application Example Picking & placing Deflection: 0.1 mm or less (For MTS12-25, within allowable lateral load values) Non-rotating accuracy: 0.1 or less (0.2 or less for 8, within allowable torque values) MX MTS8 MTS8 Reduced labor for design and assembly MTS MY Short mounting pitch: 15 mm CY Mounting is possible in high accuracy.
Precision Cylinder Precision Cylinder Precision Cylinder Non-rotating accuracy: 0.1 or less (0.2 or less for 8, within allowable torque values) New New MTS8 MTS8 Short mounting pitch: 15mm Small size 8 introduced to series 22 Rod through hole allows vacuum piping (order made) Lifting and transfer of small electronic parts is possible with short mounting pitch 15 Uses new type compact
How to Order XC38 CM2W series Vacuum (Rod through-hole) HA + Stroke ZZ + 2 x Stroke d J HA ZZ Bore size (mm) 20 25 32 40 Specifications: Same as standard type 3 M5 x 0.8 32 135 3 M5 x 0.8 32 139 3 M5 x 0.8 32 141 4 Rc1/8 36 174 XC38 MTS8 Stroke (P) Dimensions Axial piping type Vacuum (Rod through-hole) MTS8 series Use 4/2.5 urethane tube (TU0425) or use soft nylon tube (TS0425). 1 4 7 + Stroke
(P) Dimensions Axial piping type Vacuum specification (Rod through-hole type) Series MTS8 Use 4/2.5 urethane tube (TU0425) or use soft nylon tube (TS0425). 1 4 7 + Stroke 60 + 2 x Stroke Caution 1.
E Max Load Current and Load Current Range Internal Voltage Drop Indicator Lamp (Lit at ON Condition) Applications H O W T O O R D E R S E E N E X T P A G E Auto Switch No Load Voltage 24V AC/DC or less 50mA D-A90L D-A90VL 0 None PLC 48V AC/DC or less 40mA 100V AC/DC or less 20mA 24V DC 5~40mA D-A93L D-A93VL 2.6V or less PLC 100V AC 5~20mA D I M E N S I O N S S E E N E X T P A G E D-A96L
Stroke: 30mm, Rod End: M (Rod End Male Thread)
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Without end lock (
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Without end lock (
Stroke: 30mm, Rod End: M (Rod End Male Thread), Piping: Standard Porting, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Stroke: 30mm, Rod End: M (Rod End Male Thread), Piping: Standard Porting, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)
Stroke: 30mm, Rod End: M (Rod End Male Thread), Piping: Standard Porting, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal
Stroke: 30mm, Rod End: Rod End Male Thread, Piping: Standard Porting, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Stroke: 30mm, Rod End: Rod End Male Thread, Piping: Standard Porting, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Without end lock (
Cylinder (Tube) Inner Diameter(φ): 8, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Pressure(MPa): -, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 0.7, Specification: Without end lock (
Indicator light Special function Electrical entry Wiring (output) Electrical entry direction 0.5 (Nil) 3 (L) 5 (Z) Applicable loads Type DC AC Perpendicular In-line A96 A96V 3 wire (NPN equiv.) 5V IC circuit A96L A96VL Reed switch Solid state switch Yes A93 A93V 100V Grommet A93L A93VL Relay, PLC 2 wire 24V A90 A90V 5V, 12V No 100V or less IC circuit A90L A90VL F9N F9NV
Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L
, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L
Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A96L