SMC Corporation of America
Elite Part Number Search
Search Results "MGPL20TN-75AZ"

Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.333 Construction MGPM12 to 25 MGPM32 to 100 @6 @4 @4 @6 @7 @5 @5 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MGP. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) Seal Kit List Description

Bearing Type: L (Ball Bushing), Bore Size: 20mm, Thread Type: TN (NPT), Stroke: 75mm, Stroke Adjustment: A (0 to 10), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Stroke Options: XC8 (Adjustable Stroke, Extension Type)

Bearing Type: L (Ball Bushing), Bore Size: Ø20 mm, Port Thread Type: TN [NPT], Stroke: 75 mm, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L [3m]

Bearing Type: L (Ball Bushing), Bore Size: Ø20 mm, Port Thread Type: TN [NPT], Stroke: 75 mm, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, Lead Wire or Prewired Connector: L [3m]

Bearing Type: L (Ball Bushing), Bore Size: Ø20 mm, Port Thread Type: TN [NPT], Stroke: 75 mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SAPC [0.5m Cord Length, M8-3 Pin Connector]

Bearing Type: L (Ball Bushing), Bore Size: Ø20 mm, Port Thread Type: TN [NPT], Stroke: 75 mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L [3m]

Bearing Type: L (Ball Bushing), Bore Size: Ø20 mm, Port Thread Type: TN [NPT], Stroke: 75 mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z [5m]

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9N, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9NV, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9P, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9PV, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: M9PV, Lead Wire Length(m): 0.5, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: NPT, Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number