Your search for MGP returned 27 result(s)
There were no hits with the full part number, but there were 25 hits in the keyword search.
There were no hits with the full part number, but there were 16 hits in the keyword search.
Product Information » New Products Search Results
Compact Guide Cylinder/With Air Cushion Series MGP Replacement Procedure is 12, 16, 20, 25, 32 40, 50, 63, 80, 100 P.333 Construction MGPM12 to 25 MGPM32 to 100 @6 @4 @4 @6 @7 @5 @5 @7 The numbers are the same as the "Construction" of the Best Pneumatics No.3 Series MGP. *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Kit no. Contents Bore size (mm) Seal Kit List Description
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x
Bore Size: 12mm, Port Thread: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 200mm, Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal
Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x
The new style MGP has a shorter guide rod and thinner plate resulting in a weight reduction of up to 17% over the original MGP. The series is designed for high side load applications found in material handling, lifting and stopping. The cylinder utilizes an ultra-compact design by incorporating the cylinder body as part of the guide body. As the stroke length increases, so does the bearing
CK1 Load voltage Auto switch model Lead wire length (m) Pre-wired connector Applicable load DC AC Band mounting Rail mounting 0.5 (Nil) 1 (M) 3 (L) 5 (Z) None (N) Perpendicular In-line Perpendicular In-line Indicator light Type Special function Electrical entry Wiring (Output) C(L)K M9NV M9N M9NV M9N V V V v v IC circuit 3-wire (NPN) C(L)KU 5 V,12 V 3-wire (PNP) M9PV M9P M9PV M9P V V V v
MGP MGPA12-150 MGP MGPA12-100 MGPA -200 32 40 MGPA -150 32 40 MGPA -100 32 40 MGPA -200 32 32 40 40 0.2 0.4 MGP MGPA12-75 MGPA12-75 MGPA -150 32 32 40 40 0.15 0.3 MGPA -100 32 32 40 40 0.1 0.2 MGPA12-50 MGPA12-50 MGPA -50 32 40 MGPA -50 32 32 40 40 0.05 0.1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
[Bottom mounting] B Pin hole L2 Pin hole D-X B = (0.045 + L2 x 0.0016) [mm] 437 MGP Series High Precision Ball Bushing/MGPA Plate Displacement Amount (Reference Values) Load from lateral direction Displacement MGPA12 MGPA32, 40 0.8 0.4 Plate displacement amount [mm] Plate displacement amount [mm] MGPA12-250 MGPA -400 32 40 0.7 0.35 0.6 0.3 MGPA -300 32 40 MGPA12-150 MGPA12-100 MGPA12-75
/CKP150-200Z CKG163-200Z/CKP163-200Z CKG40-RZ200 D-M9/M9W D-M9A/A9 Switch mounting rod 2 Mount the part E of the auto switch mounting bracket so that it is in contact with the cylinder tube.
Pressure Control Equipment Industrial Filters @3 @1 @3 @1 @2 @2 @4 @4 MGPL12 to 25 MGPA12 to 25 MGPL32 to 100 MGPA32 to 100 @3 @1 @3 @1 @2 @2 @4 @4 The numbers are the same as the "Construction" of the MGP series catalog (CAT.ES20-219). Refer to pages 213-1 and 213-2 for replacement parts/seal kit and grease pack part numbers of Made-to-Order common specifications (-XB, -XC).
0.4 0.8 MGPA -400 32 40 32 40 MGPA12-250 MGPA12-250 MGPA -400 0.35 0.7 Plate displacement mm Plate displacement mm 0.3 0.6 MGPA -300 32 40 MGPA -300 32 40 0.25 0.5 MGPA12-150 MGPA12-150 MGPA12-100 MGPA -200 32 40 MGPA12-100 MGPA -200 32 40 0.2 0.4 MGPA12-75 MGPA12-75 MGPA -150 32 40 MGPA -100 32 40 MGPA -150 32 40 0.15 0.3 32 40 MGPA -100 MGPA12-50 MGPA12-50 0.1 0.2 MGPA -50 32 40 MGPA -
0.4 0.8 MGPA -400 32 40 32 40 MGPA12-250 MGPA12-250 MGPA -400 0.35 0.7 Plate displacement mm Plate displacement mm 0.3 0.6 MGPA -300 32 40 MGPA -300 32 40 0.25 0.5 MGPA12-150 MGPA12-150 MGPA12-100 MGPA -200 32 40 MGPA12-100 MGPA -200 32 40 0.2 0.4 MGPA12-75 MGPA12-75 MGPA -150 32 40 MGPA -100 32 40 MGPA -150 32 40 0.15 0.3 32 40 MGPA -100 MGPA12-50 MGPA12-50 0.1 0.2 MGPA -50 32 40 MGPA -
MGP MGPA12-150 MGP MGPA12-100 MGPA -200 32 40 MGPA -150 32 40 MGPA -100 32 40 MGPA -200 32 32 40 40 0.2 0.4 MGP MGPA12-75 MGPA12-75 MGPA -150 32 32 40 40 0.15 0.3 MGPA -100 32 32 40 40 0.1 0.2 MGPA12-50 MGPA12-50 MGPA -50 32 40 MGPA -50 32 32 40 40 0.05 0.1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
Pressure Control Equipment Industrial Filters @3 @1 @3 @1 @2 @2 @4 @4 MGPL12 to 25 MGPA12 to 25 MGPL32 to 100 MGPA32 to 100 @3 @1 @3 @1 @2 @2 @4 @4 The numbers are the same as the "Construction" of the MGP series catalog (CAT.ES20-219). *BLUE links will lead to purchase pages. Replacement Parts: Seal Kit Seal Kit List Description Material Note No. Bore size (mm) Kit no.
Basic type MGPM12 to 25 MGPM32 to 100 22 MGPL12 to 25 MGPL32 to 100 MGPA12 to 25 MGPA32 to 100 23 17-2. Air cushion type MGPM 24 MGPL MGPA 18. Auto Switch 18-1.Applicable auto switches 25 26 18-2. Auto switch proper mounting position (detection at stroke end) and Its mounting height 27 18-3. Minimum mountable stroke for a cylinder with auto switch(es) 18-4.