SMC Corporation of America
Elite Part Number Search
Search Results "MACM4-20N-X131"

Allowable Load Weight: 4 [900 lbf (4KN)], Stroke: 20 (20mm, MACM4), Table Option: N (Cast Nylon), Sensor Type: P (Port Side Photo Sensor Mounted Type), Relief Port: No

Allowable Load Weight: 4 [900 lbf (4KN)], Stroke: 20mm, MACM4, Table Option: Ultra High Molecular Weight Polyethylene, Sensor Type: Port Side Photo Sensor Mounted Type, Relief Port: Yes

Allowable Load Weight: 4 [900 lbf (4KN)], Stroke: 20mm, MACM4, Table Option: Ultra High Molecular Weight Polyethylene, Sensor Type: Unsupported, Relief Port: No

Allowable Load Weight: 4 [900 lbf (4KN)], Stroke: 20mm, MACM4, Table Option: Cast Nylon, Sensor Type: Port Back Side Photo Sensor Mounted Type, Relief Port: No

Allowable Load Weight: 4 [900 lbf (4KN)], Stroke: 20mm, MACM4, Table Option: Stainless Steel, Cut Finish, Sensor Type: Unsupported, Relief Port: Yes

Allowable Load Weight: 4 [900 lbf (4KN)], Stroke: 20mm, MACM4, Table Option: Cast Nylon, Sensor Type: Port Side Photo Sensor Mounted Type, Relief Port: No

) 30 30 mm (MACM6) 50 50 mm (MACM10) Nil Unsupported P Port side photo sensor mounted type B Port back side photo sensor mounted type Specications Precautions Model MACM2-12 MACM4-20 MACM6-30 MACM10-50 Max. allowable load weight lbf [KN] 450 [2] 900 [4] 1350 [6] 2250 [10] Be sure to read this before handling the products.

Manual override Indicator light U side 300 Lead wire length 2n-Rc 1/8, 1/4, C6, C8 Double check spacer (n) Individual SUP spacer (1) (2) Stations Control unit Pressure unit Filter element Drain cock D side Outlet for check Control unit n: Stations L Stations Formula 20n + 21 20n + 176 20n + 232.5 4 101 5 121 6 141 7 161 8 181 9 201 10 221 11 241 12 261 13 281 14 301 15 321 16 341 17 361

Manual override Indicator light U side 300 Lead wire length 2n-Rc 1/8, 1/4, C6, C8 Double check spacer (n) Individual SUP spacer (1) (2) Stations Control unit Pressure unit Filter element Drain cock D side Outlet for check Control unit n: Stations L Stations Formula 20n + 21 20n + 176 20n + 232.5 4 101 5 121 6 141 7 161 8 181 9 201 10 221 11 241 12 261 13 281 14 301 15 321 16 341 17 361

F.O.F. 20N 30 O.T. 50 T.T. Adjustable Roller Lever/VM830-01-13 JIS Symbol 20N F.O.F. At lever length 38.1mm 20 P.T. 30 O.T. 50 T.T. Adjustable Rod Lever/VM830-01-14 JIS Symbol 2.3N F.O.F.

Manual override Indicator light U side 300 Lead wire length 2n-Rc 1/8, 1/4, C6, C8 Double check spacer (n) Individual SUP spacer (1) (2) Stations Control unit Pressure unit Filter element Drain cock D side Outlet for check Control unit n: Stations L Stations Formula 20n + 21 20n + 176 20n + 232.5 4 101 5 121 6 141 7 161 8 181 9 201 10 221 11 241 12 261 13 281 14 301 15 321 16 341 17 361

) 30 30 mm (MACM6) 50 50 mm (MACM10) Nil Unsupported P Port side photo sensor mounted type B Port back side photo sensor mounted type Specications Precautions Model MACM2-12 MACM4-20 MACM6-30 MACM10-50 Max. allowable load weight lbf [KN] 450 [2] 900 [4] 1350 [6] 2250 [10] Be sure to read this before handling the products.

R P 3.5 to 7 3 1 < >: AC 93.5 86 M plug connector (M) R P (Lead wire length) 3 1 87 300 83.5 98.5 Indicator light Cross section 0.23 mm2 Cover diameter 1.5 69.5 <74.5> R P 3 1 < >: AC Formula L1 = 20n + 8 L2 = 20n + 26 n: Stations (Maximum 20 stations) Dimensions L n 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 48 66 87.5 98 68 86 112.5 123 88 106 137.5 148 108 126 150 160.5 128 146 175

(n) (2) (1) stations (Light/Surge voltage suppressor) Connector polarity indication Applicable connector: 26 pins MIL (Conforming to MIL-C-83503) SS5X3-20N Connector polarity indication n: Stations (n1 + n2) Stations n 4 72.5 64.5 5 85 77 6 97.5 89.5 7 110 102 8 122.5 114.5 9 135 127 10 147.5 139.5 11 160 152 12 172.5 164.5 L1 L2 1-6-51 52 SX5000: SS5X5-20PStations 2-One-touch fittings (

One Way Roller Lever/VFM350-02-02, VFM350-02-02S JIS Symbol 7N F.O.F. 0.5MPa supply 2.4mm P.T. 4.6mm O.T. 7mm T.T. 3.5-49 VFM300 Series VFM300 Straight Plunger/VFM350-02-05 Panel mounted hole SA JIS Symbol VA SA VA 20N F.O.F. 0.5MPa supply 1.5mm P.T. 2mm O.T. VM/VR 3.5mm T.T.

Allowable external resistance Nominal size Allowable external resistance 16 10N 25 20N When the floating bracket is used Installation of a holding bolt. Install the pin and the conical spring washer in the slider with a holding bolt.

The MB series medium duty tie rod cylinder offers an improved design that enhances cylinder operation and ease of use. The standard air cushion utilizes a floating cushion seal to eliminate piston rod bouncing. The cushion volume has been elevated permitting about 30% more allowable kinetic energy absorption. The port and captive cushion adjustment valve are located on the same side of cap

H=0.1 m Fs=20 N If MSUA7 is selected under those conditions, thrust load of 20N will be within the allowable value of 60N, Fig.3 but moment will be 20N X 0.1m=2Nm, and it exceeds the allowable moment of 0.9Nm, so that it can not be used.