SMC Corporation of America
Elite Part Number Search
Search Results "LVM10R3-5E-2"

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: K (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KO (Plug Connector, w/o Connector)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KZ (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: K (Plug Connector, 300mm)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KO (Plug Connector, w/o Connector)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Y (Power-saving Circuit), Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KZ (Plug Connector, 300mm)

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Standard, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: 1000mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, w/o Connector, CE Compliant: -

Symbol: Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT, Function: Power-saving Circuit, Voltage: 24 VDC, Wetted Part Material: Plate: PFA; Diaphragm: EPDM, Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: Manual Override, Lead Wire Length: Plug Connector, 300mm, CE Compliant: -

Please contact us for the latest version.sales@ocaire.com, VALVE, CHEMICAL, BASE MOUNTED, VALVE, LVM CHEMICAL VALVE, 2 PORT, 2A, LVM BODY PORT, NO SIZE RATING, .08818 lb, ModelValve constructionValve typeNumber of portsFluid Note 1)Operating pressure rangeOrifice diameterResponse timeLeakageProof pressure Note 2)Ambient temperatureFluid temperatureVolume of valve chamberMounting orientationEnclosureWeightRated

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: 10 (1000mm), CE Compliant: Q (CE Compliant)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KO (Plug Connector, w/o Connector), CE Compliant: Q (CE Compliant)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: K (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)

Symbol: 10R4 (Base Mounted, 2 Port, N.O., Port 3 IN, Port 2 OUT), Function: Standard, Voltage: 5 (24 VDC), Wetted Part Material: E (Plate: PFA; Diaphragm: EPDM), Sub-plate Material, Port Size, Reverse Mounting Prevention Pin: w/o Sub-plate, Option: 2 (Manual Override), Lead Wire Length: KZ (Plug Connector, 300mm), CE Compliant: Q (CE Compliant)