SMC Corporation of America
Elite Part Number Search
Search Results "LEYG25LDEA-150C-C617"

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: None, Controller: C61 [Parallel Input (PNP)], Mounting: 7 (Screw Mounting)

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Guide Option: w/o Option, Actuator Cable Type, Length: None, Controller: C61 [Parallel Input (PNP)], Mounting: Screw Mounting, I/O Cable: -, Communication Plug Connector: -

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover)

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Motor Cover, Guide Option: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -

Size: 25, Bearing Type: L (Ball Bushing Bearing), Motor Mounting Position: D (In-line), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Guide Option: w/o Option, Actuator Cable Type, Length: R3 (3m), Controller: C61 [Parallel Input (PNP)], Mounting: 7 (Screw Mounting), I/O Cable: 3 (I/O Cable, 3m)

Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting Position: In-line, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Motor Cover, Guide Option: w/o Option, Actuator Cable Type, Length: 3m, Controller: C61 [Parallel Input (PNP)], Mounting: Screw Mounting, I/O Cable: I/O Cable, 3m, Communication Plug Connector: -

Size: 25, Motor Mounting Position: Top Mounting, Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: None, Controller: C61 [Parallel Input (PNP)], Mounting: 7 (Screw Mounting)

Size: 25, Motor Mounting Position: Top Mounting, Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: None, Controller: C61 [Parallel Input (PNP)], Mounting: Screw Mounting, I/O Cable: -, Communication Plug Connector

-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) * Not available with switch & with air cushion VMounted on the product. vPlease order separately.

(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.

Symbol Nil None A B C Changed part XVD Without indicator With indicator Without indicator With indicator XLF100-30-1 XLF100A-30-1 XLF100-30-1H XLF100A-30-1H 5 to 60C 8-1 8-2 XGT 8-1 5 to 150C 8-2 Temperature specifications Symbol Nil 5 to 60C 5 to 150C H0 CYV Temperature Seal material: Same as the seal materials of How to Order Valve Same as How to Order Specifications Valve type Shaft seal

Nominal filtration rating: 0.01 m [Filtration efficiency: 99.9%] Oil mist density at outlet: Max. 0.1 mg/m3 (ANR) [0.08 ppm] 150C 1/8, 1/4 200 250C 1/4, 3/8 500 350C 3/8, 1/2 1,000 Piping support type 450C AMH 1/2, 3/4 2,000 550C 3/4, 1 3,700 1, 1 1/2 650 6,000 1 1/2, 2 850 12,000 AMH150C to 550C AMH650/850 150C 1/8, 1/4 200 Dust filtration, Oil mist adsorption Dust filtration, Oil mist adsorption

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes

cylinder can create a gas that is hazardous to humans. 1729 C Made to Order Common Specifications: -XB6: Heat Resistant Cylinder (10 to 150C) Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 2 CY3B series How to Order Temperature Range for Operating Cylinder and Piston Speed 1.

) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.

Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm SMC test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.