SMC Corporation of America
Elite Part Number Search
Search Results "LEY63S4L-100BML-S2"

(Unit:mm/s2) Refer to (1) to (5) on page 53 for acceleration speed setting for movement mode. Acceleration 1 to Max ACC/DEC in the basic parameters Set the deceleration from travel speed to stop. (Unit:mm/s2) Refer to (1) to (5) on page 53 for deceleration speed setting for movement mode.

(Unit:mm/s2) Refer to (1) to (5) on page 53 for acceleration speed setting for movement mode. Acceleration 1 to Max ACC/DEC in the basic parameters Set the deceleration from travel speed to stop. (Unit:mm/s2) Refer to (1) to (5) on page 53 for deceleration speed setting for movement mode.

(Unit:mm/s2) Acceleration 1 to Max ACC/DEC in the basic parameters Refer to (1) to (5) on page 54 for acceleration speed setting for movement mode. Set the deceleration from travel speed to stop. (Unit:mm/s2) Deceleration 1 to Max ACC/DEC in the basic parameters Refer to (1) to (5) on page 54 for deceleration speed setting for movement mode.

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor

Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: L (2.86mm), Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: L (Foot), Cable Type: R (Robotic Cable, Flexible Cable), Cable Length: 2m

Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: 2.86mm, Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Foot, Cable Type: Robotic Cable, Flexible Cable, Cable Length: 2m, Driver Type: -, I/O Connector:

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.High output motor

Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: C (5mm), Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: L (Foot), Cable Type: S (Standard Cable), Cable Length: 2m

Accuracy: Basic, Motor Mounting Position: Top Mounting, Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: 5mm, Stroke: 100mm, Dust/Drip Proof: IP5x (Dust Proof Specification), Motor Option: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: Foot, Cable Type: Standard Cable, Cable Length: 2m, Driver Type: -, I/O Connector: -

EtherNet/IP 3.5 1 LED :ON PWR :OFF : : : RUN :USB USB :USB : ALM : LED PWR PWR Modbus -11No.JXC-OMT0001CN-C (2) /SMC/JXC Controller (N) () OK -12No.JXC-OMT0001CN-C () USB USB (3) 13.2 -13No.JXC-OMT0001CN-C 3.6 1 View(V) parameter actuator selection -14No.JXC-OMT0001CN-C Search from Part No.area Result Result Search from Part No. area (LER ) ) LEY16RA-100BML LEY16RA

(When the LER series is used, enter the part number including the rotation angle). e.g. 1) For LEY16RA-100BML, enter "LEY16RA-100". e.g. 2) For LERH30K-3L, enter "LERH30K-3".

(When the LER series is used, enter the part number including the rotation angle). e.g. 1) For LEY16RA-100BML, enter "LEY16RA-100". e.g. 2) For LERH30K-3L, enter "LERH30K-3".

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use o, Rod Type Electric Actuator, ELECTRIC ACTUATOR, 6.36 lb

Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: L (Foot)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: L (Foot)

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: L (Foot)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: L (Foot)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: L (Foot)

Size: 25, Motor Mounting Position: Top, Motor: A [Servo Motor (24 VDC)], Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: B (w/Lock), Rod End Thread: M (Male), Mounting: L (Foot)

Size: 32, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Lock, Rod End Thread: Male, Mounting: Foot, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for