SMC Corporation of America
Elite Part Number Search
Search Results "LEY40DEB-400W-R5CL17"

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 200mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included)

Size: 40, Motor Mounting Position: In-line, Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Male Thread, 1 Rod End Nut is Included, Mounting: -, Actuator Cable Type, Length: -, Controller: -, Mounting: -, I/O Cable: -, Communication Plug Connector: -

without brake 400W with brake 400W without brake 400W with brake Symbol A B C D G H J K Motor specifications Mitsubisi Electric Corporation, Yaskawa Electric Corporation, OMRON Corporation Standard strokes are available in 50 mm increments.

For driver of 200W to 400W, regenerative resistor is not used. 02:LEC-MR-RB-032 03:LEC-MR-RB-12 Selection of regenerative option 00: Regenerative option is not used For servo amplifier of 100W, regenerative resistor is not used. For servo amplifier of 200 to 400W, built-in regenerative resistor is used. 02: MR-RB032 03: MR-RB12 4 6 4.

Driver Type Motor type Encoder Type Capacity C CC-Link type Absolute encoder S5 100W AC Servo motorS6*1 Absolute S7 200W AC Servo motorS7*1 S8 400W AC Servo motorS8*1 *1 This is a symbol of motor type (actuator part).

Driver type Driver select Motor select SMC Sigma Win+ SMC Sigma Win+ V5 SGDV-R90*11*Y572AA V6 SGMJV-01A3A2* 100W 200W V7 SGDV-1R6*11*Y572AA V7 SGMJV-02A3A2* LECYM2-** MECHATROLINK 400W V8 SGDV-2R8*11*Y572AA V8 SGMJV-04A3A2* V5 SGDV-R90*21*Y572AA V6 SGMJV-01A3A2* 100W MECHATROLINK 200W V7 SGDV-1R6*21*Y572AA V7 SGMJV-02A3A2* LECYU2-** 400W V8 SGDV-2R8*21*Y572AA V8 SGMJV-04A3A2* Trademarks

Driver type Driver select Motor select SMC Sigma Win+ SMC Sigma Win+ V5 SGDV-R90*11*Y572AA V6 SGMJV-01A3A2* 100W 200W V7 SGDV-1R6*11*Y572AA V7 SGMJV-02A3A2* LECYM2-** MECHATROLINK 400W V8 SGDV-2R8*11*Y572AA V8 SGMJV-04A3A2* V5 SGDV-R90*21*Y572AA V6 SGMJV-01A3A2* 100W MECHATROLINK 200W V7 SGDV-1R6*21*Y572AA V7 SGMJV-02A3A2* LECYU2-** 400W V8 SGDV-2R8*21*Y572AA V8 SGMJV-04A3A2* Trademarks

Driver Type Motor type Encoder Type Capacity C CC-Link type Absolute encoder T5 100W AC Servo motorT6*1 T7 200W AC Servo motorT7*1 Absolute T8 400W AC Servo motorT8*1 T9 AC Servo motorT9*1 750W Power supply *1 This is a symbol of motor type (actuator part).

INSTALLATION (b) Installation of two or more drivers POINT Close mounting is available for the driver of under 3.5kW for 200V class and 400W for 100V class. Leave a large clearance between the top of the driver and the internal surface of the control box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the environmental conditions.

INSTALLATION POINT Close mounting is available for the driver of under 3.5kW for 200V class and 400W for 100V class. Leave a large clearance between the top of the driver and the internal surface of the control box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the environmental conditions.

Protocol: 9 (EtherNet/IPâ„¢), Mounting: 8 (DIN Rail), Cable Connector: None, Actuator: LEY, Body Size: 40, Motor Mounting: D (In-line), Lead: B (16: 5mm; 25: 6mm; 12; 32/40: 8mm), Stroke: 200mm

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R3 (3m), Controller: CP1 (PROFINET), Mounting: 7 (Screw Mounting)

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R3 (3m), Controller: C51 [Parallel Input (NPN)], Mounting: 8 (DIN Rail), I/O Cable: 3 (I/O Cable

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 500mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R3 (3m), Controller: C51 [Parallel Input (NPN)], Mounting: 8 (DIN Rail), I/O Cable: 3 (I/O Cable

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R3 (3m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)

Size: 40, Motor Mounting Position: D (In-line), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut is Included), Mounting: F (Rod Flange, Top Mounting & In-line), Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 7 (Screw Mounting)