SMC Corporation of America
Elite Part Number Search
Search Results "LEY40C-500C"

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 500mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 500mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 500mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 500mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 17.63697 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 17.63697 lb

53 Horizontal work load [kg] 80 Vertical work load [kg] 40 Lead 4: LEY40C 60 Lead 8: LEY40B Lead 8: LEY40B 27 40 20 30 Lead 16: LEY40A 13 20 Lead 16: LEY40A 0 0 0 300 400 500 200 100 600 0 300 400 500 200 100 600 Speed [mm/s] Speed [mm/s] 225 LEY Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Refer to page 224 for the LECP6, LECP1, LECPMJ, and page 225 for the LECPA.

Response Frequency 100Hz (10ms) Operating Temperature Range 0~500C (air should not be frozen) / 32~120F Temperature 25+-10 0C +-0.3% F.S. or less Characteristic* 0-500C /32~120F +-0.5% F.S. or less Repetition Accuracy +-0.2% F.S. or less Noise Resistance 500Vp-p pulse width 1s standing 1ns Withstand Voltage Between whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance

Response Frequency 100Hz (10ms) Operating Temperature Range 0~500C (air should not be frozen) / 32~120F Temperature 25+-10 0C +-0.3% F.S. or less Characteristic* 0-500C /32~120F +-0.5% F.S. or less Repetition Accuracy +-0.2% F.S. or less Noise Resistance 500Vp-p pulse width 1s standing 1ns Withstand Voltage Between whole wires and case 1000VAC 50/60Hz for one minute Insulation Resistance

400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120 1200 90 1200 10 250 1400 150 1400 100 1400 11 300 1600 180 1600 110 1600 12 350 1800 210 1800 120 1800 13 400 2000 240 2000 130 2000 14 450 2500 270 2500 140 2500 15 500 3000 300 3000 150 3000 LEY40A / LEYG40A LEY40B / LEYG40B LEY40C

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-200, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

This is a legacy product, and replaced byC96SB100-500C

This is a legacy product, and replaced byCP96SDB80-500C, CYL, PROFILE, ISO, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW, 17.81286 lb

This is a legacy product, and replaced byCP96KDB40-500C, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, ME, 40MM C95/CP95 DBL-ACT AUTO-SW, 2.84395 lb

This is a legacy product, and replaced byC96SDC50-500C, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, NE, 50MM C95/CP95 DBL-ACT AUTO-SW, 4.80607 lb

VVQ1000-1-J A&C M VVQ1000-1-J B&D M Nozzle Diameter (mm) 0.7 1 Max Suction Flow Rate (Nl/min) 11 20 Max Vacuum Pressure -630mmHg Max Operating Pressure 0.8MPa / 120PSI Standard Supply Pressure 0.5Mpa / 70PSI Operating Temperature 5~500C / 40~120F T E C H N I C A L SPECIFICATIONS EJECTOR UNITS H O W T O O R D E R Vacuum Ejector Unit Max No of Units No of Valve Stations 6 0-3 5 4-6 4 7-10 3

This is a legacy product, and replaced byCP96SDB100-500C, CYL, PROFILE, ISO, ACTUATOR, C95/C96 TIE-ROD CYLINDER, SE, 100MM C95/CP95 DBL-ACT AUTO-SW, 21.62981 lb