SMC Corporation of America
Elite Part Number Search
Search Results "LEY40C-30BL"

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 30mm, Motor Option: w/Lock, Rod End Thread: Female, Mounting: Foot, Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

53 Horizontal work load [kg] 80 Vertical work load [kg] 40 Lead 4: LEY40C 60 Lead 8: LEY40B Lead 8: LEY40B 27 40 20 30 Lead 16: LEY40A 13 20 Lead 16: LEY40A 0 0 0 300 400 500 200 100 600 0 300 400 500 200 100 600 Speed [mm/s] Speed [mm/s] 225 LEY Series Step Motor (Servo/24 VDC) Servo Motor (24 VDC) Refer to page 224 for the LECP6, LECP1, LECPMJ, and page 225 for the LECPA.

Please contact us for the latest version.sales@ocaire.com, LEVER HOLDER (RSH50-30BL), ACTUATOR, RSH STOPPER CYLINDER, N1, 50MM RSH PART, .47300 lb, ModelBore size (mm)ActionStyle of rod endFluidProof pressureMax. operating pressureAmbient and fluid temperatureLubricationCushionStroke length toleranceMountingPort size Rc, NPT, GRSH20Double acting, Double acting spring, Single acting

Please contact us for the latest version.sales@ocaire.com, LEVER (RSH50-30BL), ACTUATOR, RSH STOPPER CYLINDER, N1, 50MM RSH PART, .26510 lb, ModelBore size (mm)ActionStyle of rod endFluidProof pressureMax. operating pressureAmbient and fluid temperatureLubricationCushionStroke length toleranceMountingPort size Rc, NPT, GRSH20Double acting, Double acting spring, Single acting (Spring

400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120 1200 90 1200 10 250 1400 150 1400 100 1400 11 300 1600 180 1600 110 1600 12 350 1800 210 1800 120 1800 13 400 2000 240 2000 130 2000 14 450 2500 270 2500 140 2500 15 500 3000 300 3000 150 3000 LEY40A / LEYG40A LEY40B / LEYG40B LEY40C

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-200, I/O cable length / communication plug(m): 1.5, Controller/driver mounting method: DIN rail mounting type

Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY40C-50, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Magnet: None, Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: None, Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)

Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 40mm, Water Resistant: None, Port Thread: TF (Bore 20: M5 Thread, Bore 32 to 50: G), Stroke: 30mm, Action: B (Double Acting/Spring Loaded), Rod End: L (Lever Type, Fixed Absorber Type)