Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input Type), I/O Cable Length
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for LEC
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 5m, Controller
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 7.88152 lb
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
) 100 40 LECSB-S5 LECSC-S5 LECSS-S5 Nil Without option B With lock 200 to 1500 LEH *3 Refer to the applicable stroke table for details.
A4 (2) LECSS150%55 (3) (SCCRShort Circuit Current Rating) UL100kA(500V) (4) [mm] LE-2502506 S5S6S7 25025012 S8 (5) 1530KW20 [min] LECSS2-S5 LECSS2-S7 1 LECSs2-S8 LECSS1-S5 LECSS1-S7 2 12 (6) 70% 04575 LECSS-(115% (full load current)) 1000 1000 100 100 10 10 [s] 1 1 0.1 0.1 0 50 150 200 250 300 100 0 50 150 200 250 300 100 [] [] LECSS-S5 LECSS-S7LECSS2-S8 13 (7) UL/cULUL60/75 60[AWG
Regenerative power [W] Built-in regenerative Driver LEC-MR-RB-032 LEC-MR-RB-12 [40] [40] resistor LECSB-S5 30 LECSB-S7 10 30 100 LECSB-S8 10 30 100 Note 1. Always install a cooling fan. 2.
2000 50 2000 100 2000 90 2000 10 150 2500 75 2500 150 2500 100 2500 11 200 3000 100 3000 200 3000 110 3000 12 250 3500 125 3500 250 3500 120 3500 13 300 4000 150 4000 300 4000 130 4000 14 350 4500 175 4500 350 4500 140 4500 15 400 5000 200 5000 400 5000 150 5000 60 No.
When you carry out adhesion mounting of the driver, make circumference temperature into 0 to 45 , or use it at 75% or smaller effective load ratio. 1000 1000 During operation During operation 100 100 Operation time[s] Operation time[s] During servo lock During servo lock 10 10 1 1 0.1 0.1 0 50 150 200 250 300 100 0 50 150 200 250 300 100 (Note) Load ratio [%] (Note) Load ratio [%] LECSS-S5
Stroke [mm] 11-LEFS25 12 6 11-LEFS32 16 8 11-LEFS40 20 10 25 32 40 100 to 1000 Symbol A B Symbol Type Actuator size Output (W) Compatible drivers 100 to 1000 S2 S3 S4 LECSA;-S1 LECSA;-S3 LECSA2-S4 LECSB;-S5 LECSC;-S5 LECSS;-S5 LECSB;-S7 LECSC;-S7 LECSS;-S7 LECSB2-S8 LECSC2-S8 LECSS2-S8 25 32 40 100 200 400 AC servo motor (Incremental encoder) Refer to the applicable stroke table. / Motor
LECSC2-S5 LECSC2-S7 LECSC2-S8 LECSC1-S5 LECSC1-S7 LECSC1-S8 Driver Power supply L1 L2 L3 Main circuit power supply 3-phase 200 to 230VAC, 50/60Hz L1L2L3 1-phase 200 to 230VAC, 50/60Hz L1L2 1-phase 100 to 120VAC, 50/60Hz L1 L2 When using driver built-in regenerative resistor, connect P( ) and D.
100 10 10 [s] [s] 1 1 0.1 0.1 0 50 150 200 250 300 100 0 50 150 200 250 300 100 ()[] ()[] LECSC-S5 LECSC-S7, LECSC-S8 . ()30r/min100% 12.1 12 2 12 12.2 (1) 12.1 12.1 1 (2)[W] (1) [m2] [kVA] LECSC-S5 LE-S5LE-S60.3 25 15 0.5 LECSC-S7 LE-S70.5 25 15 0.5 LECSC-S8 LE-S80.9 35 15 0.7 1.
;-S3 200 63 (Incremental encoder) 200 LECSB;-S5 LECSC;-S5 LECSS;-S5 LECSB;-S7 LECSC;-S7 LECSS;-S7 to 3: Refer to the table AC servo motor S6 100 40 1500 below for details.
A Controller type Motor type Power supply voltage Symbol Type AC servo motor (S2) Capacity Encoder LECSA1-S1 LECSA1-S3 LECSA2-S1 LECSA2-S3 LECSA2-S4 LECSB1-S5 LECSB1-S7 LECSB2-S5 LECSB2-S7 LECSB2-S8 AC servo motor (S2) 100 to 120 VAC 50/60 Hz S1 S3 S4 S5 S7 S8 100 W B Pulse input type (For absolute encoder) AC servo motor (S3) Pulse input type (For incremental encoder) Incremental AC servo
dual 3-port valve Operating pressure range Internal pilot operating pressure range (MPa) 0.1 to 0.7 (High pressure type: 0.1 to 1) 100 kPa to 0.7 (4-position: 100 kPa to 0.6) 100 kPa to 0.7 (High pressure type: 100 kPa to 1) 2-position single 2-position double 3-position External pilot operating pressure range (MPa) Pilot pressure range 0.25 to 0.7 0.1 to 0.7 (High pressure type: 0.1 to
100 LECSS1-S7 200 LECSS2-S5 100 LECSS2-S7 200 LECSS2-S8 400 Model Compatible motor capacity [W] Absolute 18-bit encoder (Resolution: 262144 pulse/rev) Compatible encoder Single phase 100 to 120 VAC (50/60 Hz) Three phase 200 to 230 VAC (50/60 Hz) Single phase 200 to 230 VAC (50/60 Hz) Power voltage [V] Main power supply Three phase 170 to 253 VAC Single phase 170 to 253 VAC Single phase