SMC Corporation of America
Elite Part Number Search
Search Results "LEY40B-300W-RCC918"

The cooling capacity will be reduced by 300W when option T and MT [High head pump] are selected. 5 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. is lower than 10oC. 6 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.

Applicable model HRR012/018/024/030-A/W-T1 Rated flow50/60Hz*1 L/min 10 (0.28MPa) Maximum pump head Pump 50/60Hz*2 m 40 Output W 400 Circuit protector A 15 Recommended earth leakage breaker capacity A 15 The cooling capacity reduces about 300W from the value in the catalog.

Facility water temp. 25 1500 Cooling capacity[W] 1500 25 Cooling capacity[W] 32 32 35 35 1000 1000 500 500 0 0 10 15 20 25 30 35 40 10 15 20 25 30 35 40 Circulating fluid temperature[] Circulating fluid temperature[] 50Hz 60Hz The cooling capacity will be reduced by 300W when option: T1 is selected.

005: 500W 007: 750W Heat Exchanger 9.1.2 Manufacturing code indication H E D 0 0 7 H W 13 > Recirculating fluid tube size 13: 1/2X3/8 19: 3/4X5/8 > Cooling method W: Water-cooled > Product name H: Heat Exchanger > Cooling capacity 003: 300W 005: 500W 007: 750W SERIAL No.

in cae of option: T Fig 9.4-1 Cooling capacity(HRS018-A-20-R) 9.4.2 HRS030-A-20--R The cooling capacity will be reduced by 300W in case of option: T.

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: W (with Lock/Motor Cover)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: with Lock/Motor Cover, Rod End Thread: -, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length

The cooling capacity will be reduced by 300W when option T and MT [High head pump] are selected. 5 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. is lower than 10oC. 6 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.

The cooling capacity will be reduced by 300W when option T [High pressure pump] are selected. 4 Use a 15% ethylene glycol aqueous solution if operating in a place where the circulating fluid temp. is lower than 10 oC. 5 Outlet temp. when the circulating fluid flow is rated flow, and the circulating fluid outlet and the return are directly connected.

40 400 23 400 20 400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120 1200 90 1200 10 250 1400 150 1400 100 1400 11 300 1600 180 1600 110 1600 12 350 1800 210 1800 120 1800 13 400 2000 240 2000 130 2000 14 450 2500 270 2500 140 2500 15 500 3000 300 3000 150 3000 LEY40A / LEYG40A LEY40B

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 300mm, Motor Option: W (with Lock/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 1 (1.5m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct Input

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 300mm, Motor Option: with Lock/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length

method Cooling/heating automatic shift PWM control Cooling / Heating method Thermoelectric device (Thermo-module) Liquid Tank Water-cooled Radiating method Controller Forcible air-cooled Operating temp. range -15.0 to 60.0oC (5oC or more for water) (Note 1) (Note 5) Temp. stability 0.01oC (Note 1) Temp. distribution 0.02oC (Note 1) Cooling capacity 140W (Water) (Note 2) Heating capacity 300W

Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.

(Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1. Number of step data (Points) I/O cable length [m] 2 2 stroke end points/ 12 intermediate points (Programless) Nil Without cable 1 1.5 3 3 5 5 Parallel I/O type N NPN P PNP The controller is sold as single unit after the compatible actuator is set.

Compatible motor Actuator part number P Step motor (Servo/24 VDC) (Except cable specifications and actuator options) Example: Enter LEMB25T-300 for the LEMB25T-300W-S12N1.

(0.35MPa) With leakage detection function Operating temperature range:50 to 140F (10 to 60C) Temperature stability: 0.18F (0.1C) Cooling capacity (with water): 300W, 500W, 750W International standards: SEMI Standard S2-0706, F47-0706 Environment friendly: RoHS 171 Allows direct control of chemical temperature. Allows direct control of chemical temperature.

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Table Accuracy: H (High Precision), Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: C (20), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length