Search Results "LEY40B-250F-S36N1"

Dimensions (1) Bore size: 125 Product number Bore size (mm) Stroke (mm) IN-777-125TF-250F-HL 125 250 20 (2) Bore size: 160 Product number Bore size (mm) Stroke (mm) IN-777-160TF-200F*-HL 200 160 IN-777-160TF-300F*-HL 300 21 (3) Bore size: 200 Product number Bore size (mm) Stroke (mm) IN-777-200TF-200F*-HL 200 200 IN-777-200TF-300F*-HL 300 22 (4) Bore size: 250 Product number Bore size (mm

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for

Keep this operation manual accessible for reference. 5 No.JXC-OMW1019-A 2.2 How to Order The part number construction for this product is as follows: With JOG input terminal, WAREA output function (Number of step data: 32 points) U Controller UCompatible Electric actuator model Step motor(Servo / 24VDC) P6 Stroke example: For LEFS25B-100B-S36N1, specify LEFS25B-100.

40 400 23 400 20 400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120 1200 90 1200 10 250 1400 150 1400 100 1400 11 300 1600 180 1600 110 1600 12 350 1800 210 1800 120 1800 13 400 2000 240 2000 130 2000 14 450 2500 270 2500 140 2500 15 500 3000 300 3000 150 3000 LEY40A / LEYG40A LEY40B

Otherwise, the controller, PC or equipment may be damaged. 7 - 2.3 How to Order The part number construction for this product is as follows: Electric actuator model Controller Stroke example: For LEFS25B-100B-S36N1, specify LEFS25B-100. Compatible Rotating angle: For LER10K-2L-R16N1D, P Step motor (Servo / 24 VDC) specify LER10K-2.

Temperature 45.30 38.30 8-5/8 2 18 215 AFW1400-N30FGM-E* 1,400 48.20 38.40 10.80 3 18 326 4 AFW2100-N40FGM-E* 2,100 50.30 39.30 12.80 4 20 439 AFW2800-N60FGM-E* 2,800 6 50.30 39.30 12.80 5 20 439 AFW3500-N60FGM-E* 3,500 54.30 40.40 14 6 20 536 AFW4200-N60FGM-E* 4,200 E D EL-AFW700-E* 55.10 40.60 16 8 24 647 AFW5600-N80FGM-E* 5,600 232 psi 32 8 250F 58.10 40.60 18 10 28 778 AFW7000-N80FGM-E

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange), Actuator Cable: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for LEC: 1 (1.5m)

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: F (Rod Flange), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type), I/O Cable Length for LEC: 1 (

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting: -, Communication

Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Female, Mounting: Rod Flange, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller: LECP6, Step Data Input Type, NPN, I/O Cable Length: 1.5, Communication Plug Connector: -, Controller Option: -

Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Standard Cable, Actuator Cable Length: 3, Controller: LECP6, Step Data Input Type, NPN, I/O Cable Length: 1.5, Communication Plug Connector: -, Controller Option: -

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ROD TYPE, ACTUATOR, ELECTRIC ACTUATOR, MC, 40MM LE ELECTRIC ACTUATOR, 1.54323 lb

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting

Size: 16, Motor Mounting Position: R (Basic Type), Motor Type: Step Motor, (Servo/24 VDC), Lead: K (LES8: 4mm; LES16: 5mm; LES25: 8mm), Stroke: 30mm, Motor Option: w/o Lock, Body Option: Basic Type, Mounting: w/o Side Holder, Actuator Cable Type: S (Standard Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6N [LECA6, (Step Data Input Type), NPN], I/O Cable Length for LEC