Make sure workpieces mounted on the table do not interfere with other workpieces or the facilities around the table. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed [mm] Model L A B n D E Without lock With lock LEFS40Em-150m 506 555 156 328 4 150 LEFS40Em-200m 556 605 206 378 6 2 300 LEFS40Em-250m 606 655 256 428 6 2 300 LEFS40Em-300m
19 300 15 300 2 40 400 23 400 20 400 3 48 500 27 500 30 500 4 56 600 32 600 40 600 5 64 700 44 700 50 700 6 80 800 54 800 60 800 7 100 900 77 900 70 900 8 150 1000 90 1000 80 1000 9 200 1200 120 1200 90 1200 10 250 1400 150 1400 100 1400 11 300 1600 180 1600 110 1600 12 350 1800 210 1800 120 1800 13 400 2000 240 2000 130 2000 14 450 2500 270 2500 140 2500 15 500 3000 300 3000 150 3000 LEY40A
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: -, Actuator Cable: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable Length for JXC:
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 500mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 500mm, Motor Option: None, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 5m, Controller
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 5m,
Setting of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.
Table 5.3-12 List of set values Set values Explanation Initial value (Default setting) Setting/checking are not available unless the serial protocol setting is simple communication protocol. to Setting of response delay time Set range is 0 to 250m sec. Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once.
Sets of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.
Setting of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.
Setting of response delay time Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 23. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 24.
Set range is 0 to 250m sec. to Communication range (simple communication protocol) Setting and checking 27. Press the [SEL] key once. The set screen of communication range (simple communication protocol) is displayed on the digital display. PV SV 28. Select communication range (simple communication protocol) from the table below with [] key or [] key, and confirm by pressing SEL.
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller: LECPMJ, CC-Link, Direct Input Type, I/O Cable Length: Without Cable, Communication Plug Connector
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m)
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 250mm, Motor Option: None, Rod End Thread: M (Male), Mounting: Both Ends Tapped (Standard), Actuator Cable: S (Standard Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: 6N (LECA6, NPN, Step Data Input Type), I/O Cable Length for
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug
Size: 40, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 250mm, Motor Option: None, Rod End Thread: Male, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC: 3m, Controller
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting