Your search for LEY32 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 8 hits in the keyword search.
Product Information » New Products Search Results
Lead 4: LEY32EC 80 40 43 Horizontal work load [kg] Vertical work load [kg] 70 Lead 8: LEY32EB 60 30 40 45 50 Lead 8: LEY32EB Lead 16: LEY32EA 20 22 30 Lead 16: LEY32EA 10 11 20 10 0 300 200 400 100 500 600 0 0 300 200 400 100 500 600 0 Speed [mm/s] Speed [mm/s] LEY40mE LEY40mE for acceleration/deceleration: 2000 mm/s2 100 60 53 Lead 4: LEY40EC Lead 4: LEY40EC 90 Horizontal work load [kg]
Cooling capacity: 150W; Heating capacity: 380W; Dimensions: 140mm x 160mm x 240mm; Temperature range setting: 4 to 60°C; Temperature stability: ±0.03°C or better depending on load stability; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE/UKCA, UL, RoHS
Cooling capacity: 150W; Heating capacity: 380W; Dimensions: 140mm x 160mm x 240mm; Temperature range setting: 4 to 60°C; Temperature stability: ±0.03°C or better depending on load stability; Power supply requirement: 24 VDC ±10%; Circulating fluid: Tap water or ethylene glycol solution (20% or less); Standards: CE/UKCA, UL, RoHS
Size: 25, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R1 (1.5m), Controller: C61 [Parallel Input (PNP)], Mounting: 8 (DIN Rail), I/O Cable: 1 (I/O Cable
Size: 25, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: D (In-line Type), Motor Type: Step Motor (Servo/24VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: W (with Lock/Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 1 (1.5m), Controller Type for (LEC, JXC): C61 (JXC61
Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: In-line Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: with Lock/Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 1.5m, Controller Type for (LEC, JXC): JXC61, Parallel PNP, Step Data Input
Size: 25, Motor Mounting Position: Top Mounting, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 1.5m, Controller: C61 [Parallel Input (PNP)], Mounting: DIN Rail, I/O Cable: I/O Cable, 1.5m, Communication
Size: 32, Motor Mounting Position: Top Mounting, Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 150mm, Motor Option: W (w/Lock/Motor Cover), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: R1 (1.5m), Controller: C91 (Ether Net/IPâ„¢), Mounting: 8 (DIN Rail)
Size: 32, Motor Mounting Position: Top Mounting, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 150mm, Motor Option: w/Lock/Motor Cover, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped, Top Mounting & In-line, Actuator Cable Type, Length: 1.5m, Controller: Ether Net/IPâ„¢, Mounting: DIN Rail, I/O Cable: -, Communication Plug Connector: -
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size.áDirectáor bracket mountings are available in three directionsáor types.á áThrust, speed and positioning * can beámanaged with the use of an optional controller.á Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size.áDirectáor bracket mountings are available in three directionsáor types.á áThrust, speed and positioning * can beámanaged with the use of an optional controller.á Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Three body sizes
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 1 (1.5), Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data Input Type), I/O Cable Length for LEC
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: w/o Cable,
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 1.5, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: w/o Cable, Controller