Your search for LEY32 returned 30 result(s)
There were no hits with the full part number, but there were 14 hits in the keyword search.
There were no hits with the full part number, but there were 8 hits in the keyword search.
Product Information » New Products Search Results
Size: 32, Motor Mounting Position: D (In-line Type), Motor: Step Motor (Servo 24 VDC), Lead Screw: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 50mm, Motor Option: C (w/Motor Cover), Rod End Thread: M (Male), Mounting: F (Rod Flange), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 5 (5m), Controller Type - LEC, JXC: C61 (JXC61, Parallel PNP, Step Data Input
Size: 32, Motor Mounting Position: In-line Type, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 50mm, Motor Option: w/Motor Cover, Rod End Thread: Male, Mounting: Rod Flange, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Lead 4: LEY32DC 50 Regenerative resistor area 60 Lead 8: LEY32DB 40 Work load [kg] Work load [kg] Lead 8: LEY32DB 30 40 Lead 16: LEY32DA 20 Lead 16: LEY32DA 20 10 0 0 0 200 400 600 800 1000 1200 0 200 400 600 800 1000 1200 Speed [mm/s] Speed [mm/s] Regenerative resistor area Applicable Motor/Driver * When using the actuator in the Regenerative resistor area, download the AC servo capacity
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
SpeedVertical Work Load Graph LEY25l (Motor mounting position: Top/Parallel, In-line) 40 Lead 3: LEY25C 30 Work load [kg] 20 Lead 6: LEY25B 16 Lead 12: LEY25A 10 8 0 0 200 600 1000 1400 Speed [mm/s] LEY32l (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) 50 60 Lead 4: LEY32DC 50 Lead 5: LEY32C 40 46 37 40 Work load [kg] Work load [kg] 30 30 Lead 8: LEY32DB
LEL 20 LEM 0 LEY LEY 0 200 400 600 800 1000 1400 1200 Speed [mm/s] LES LEY32 (Motor mounting position: Top/Parallel) LEY32D (Motor mounting position: In-line) LEPY LEPS 80 80 Lead 4: LEY32DC Lead 5: LEY32C LER Lead 8: LEY32DB 60 60 Lead 10: LEY32B Work load [kg] Work load [kg] Lead 16: LEY32DA LEH Area where the regeneration option is required.
(LCD ) 4.DIN 7 1-2 30mm No. 1-3 30mm Err6 1-4 5mm 5-10-15 5mm Err5 4.2 5 10 15 20 1.0 1.0 1.0 1.0 5.8 5mm 30mm Err6: 30 20 50mm/sec100mm/sec :50cm :0.5MPa 2. 2-1 CE2CEU2 8 NO 1 0 0 2 0 0 2 0 0 YES (kgf) (kgf) 1 0 0 8 0 NO 1 0 0 1 0 0 8 0 6 3 6 3 5 0 YES 5 0 0 0 NO 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 mm/s mm/s YES OK (), ? NO YES NO , , ?
LCD 4.DIN 30mm 30mm 10 - 2-2 30mm No. 2-3 (1), (Err6), 1 ML2B25 15 ML2B32 19 ML2B40 24 2-4 5mm 5-10-15 5mm Err5 4.2 5 10 15 20 1.0 1.0 1.0 1.0 5.8 5mm30mm Err6: 20 30 100mm/sec :50cm :0.5MPa 11 - 3 3 3 3 ML2B+CEU2 NO 1 () () YES NO () YES NO YES YES NO YES NO YES YES NO NO NO YES A 12 - A 1.
Description Standard Brass 5cm3/ min or less 50cm 3/ min or less 150cm 3/ min or less (1) (1) (2) PTFE Body Stainless steel q Note 1) Differ from the operating condition of pressure. Note 2) Heat loss at 0.5 MPa is about 5kcal/h. Note 3) Value on option "V", "M" (Non-leak, vacuum).
Main Body Peripheral Component: Peripheral Components, Input Power Supply: DC 24V, Position Detection: Incremental, I/O Module: PNP, Motor Type: Step motor (24‑V DC servo), Step data (points): 64, Actuator/cable type: LEY32DC-100, I/O cable length / communication plug(m): Without I/O cable, Controller/driver mounting method: Screw mounting type
Transmission Distance 20.5m (when using SMC cable and controller or counter) Position Detection Method Magnetive Scaled Piston Rod & Detection Head (50cm Cable, Incremental Type) Magnetive Field Resistance 14.5mT Power Supply DC10.8V26.4V (Ripple less than 1) Current Consumption 50mA(MAX.)
Tubings length (form valve): 50cm below c. Supply Pressure: 0.5MPa (for both brake and driving purposes) d.
Foot type, Flange type, Double clevis type Auto switch Reed type, Solid state type Sensor Specifications Symbol 7, 6-core twisted pair shielded wire (oil, heat & flame resistant cable) (Standard with connector ... made by TAJIMI ELECTRONICS CO., LTD., R04-J8M7.3) Cable 23m (when using SMC cable and counter) Transmission distance Magnetic scale rod
standard), Foot, Flange, Double clevis Mounting Preset counter ML1C Symbol REA Sensor Specifications REC 7, 6-core twisted pair shielded wire (oil, heat & flame resistant cable) (Standard with connector made by TAJIMI ELECTRONICS CO., LTD., R04-J8M7.3) Cable RHC 23m (when using SMC cable and counter) Transmission distance MTS Magnetic scale rod < non-rotating > Sensor head < cable length 50cm
Tajima Musen Denki Company Max Transmission Distance 20m (6 core twisted pair shielded wire) Position Detection Method Magnetive Scaled Piston Rod & Detection Head (50cm cable.